NB1L Residual Current Operated Circuit Breaker with Over-current Protection(Magnetic)

1.1 Function Personnel and fire protection: Cable and line protection against overload and short-circuits. 1.2 Selection Rated residual operating current I∆n ≤30 mA: additional protection in the case of direct contact. I∆n ≤300 mA: preventative fire protection in the case of ground fault currents. Tripping class AC class Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. A class Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase. Tripping curve B curve (3-5 In) protection and control of the circuits against  overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG NB1L Residual Current Operated Circuit Breaker with Over-current Protection PDF  

NB2LE Residual Current Operated Circuit Breaker

The NB2LE residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, rated current up to 25A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be protected. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses. CATALOG NB2LE Residual Current Operated Circuit Breaker PDF

NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection (Magnetic)

1.1 Function Personnel and fire protection: Cable and line protection against overload and short-circuits. 1.2 Selection Rated residual operating current I∆n =30 mA: additional protection in the case of direct contact. Tripping class A and AC class A class tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly or slowly increase. AC class tripping is ensured for sinusoidal, alternating residual currents, whether they be quickly or slowly increase. Tripping curve B curve (3 In-5 In) protection and control of the circuits against  overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5  In-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates CE/CB/KEMA 1.4 Add-on devices XF9 auxiliary contacts S9 shunt release V9 under voltage release OVT-1 over voltage release CATALOG NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection PDF

NB3LE Residual Current Operated Circuit Breaker with Over-current Protection

Rated residual operating current I∆n = 30 mA: additional protection in the case of direct contact. Tripping class AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase. Tripping curve B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. CATALOG NB3LE Residual Current Operated Circuit Breaker with Over-current Protection PDF

NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection

1.1 Selection Rated residual operating current I∆n = 30 mA: additional protection in the case of direct contact. Tripping class AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase. Tripping curve B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.2 Approvals and certificates CATALOG NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection PDF

NB7 Miniature Circuit Breaker

The NB7 series miniature circuit breaker is applicable to the circuit with an alternating  current of 50Hz/60Hz, rated voltage of 240/415V, and rated current up to 63A for overload protection and short circuit protection, and also for not-frequent operational transformation in the circuit under normal condition. This product can be applied to various places such as industrial, commercial, and tall buildings, and residential houses. The product meets the standards of IEC60898-1. NB7 Miniature Circuit Breaker PDF  

NBH8 Miniature Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC), short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates CATALOG NBH8 Miniature Circuit Breaker PDF

NBH8LE Residual Current Operated Circuit Breaker with over-current protection (Electronic)

1.1 Function Personnel and fire protection Cable and line protection against overload and short-circuits. 1.2 Selection I∆n = 10mA, 30mA: additional protection in the case of direct contact. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. CATALOG NBH8LE Residual Current Operated Circuit Breaker with over-current protection PDF

NC1 AC Contactor, 9~95A

1.1 Certificates: CE, KEMA, VDE, EK, UKrSEPRO, EAC,  RCC, UL; 1.2 Electric ratings: AC50/60Hz, 690V, up to 95A; 1.3 Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; Frequent start-up and control of AC contactor; 1.4 Utilization category: AC-3, AC-4; 1.5 Altitude: ≤2000m; 1.6 Ambient temperature: -5℃~+40℃; 1.7 Mounting category: Ⅲ 1.8 Mounting conditions: inclination between the mounting plane and the vertical plane should not                            exceed ±5° 1.9 Standard: IEC/EN 60947-4-1

NC2 AC Contactor, 115~800A

1.1 Certificates: NC2-115~800 CE, VDE, UKrSEPRO, EAC, RCC, UL; 1.2 Electric ratings: AC50/60Hz, up to 690V, up to 800A; 1.3 Application: remote making & breaking circuits  protect circuit from overload when assembling with thermal over-load relay; 1.4 Ambient temperature: -5℃~+40℃; 1.5 Altitude: ≤2000m; 1.6 Mounting category: Ⅲ 1.7 Mounting conditions: inclination between the mounting plane and the vertical plane not exceed ±5° 1.8 Standard: IEC/EN 60947-4-1

NC6 AC Contactor, 6~9A

1.1 Certificates: CE, VDE, UKrSEPRO, EAC, UL; 1.2 Electric ratings: AC50/60Hz, up to 690V, up to 9A; 1.3 Application: remotely makes and breaks circuit, protect circuit from overload assembling with proper thermal relay; 1.4 Utilization category: AC-1, AC-3, AC-4; 1.5 Ambient temperature: -5℃~+40℃; 1.6 Altitude: ≤2000m; 1.7 Mounting category:  Ⅲ .1.8 Mounting conditions: inclination between mounting plane and vertical plane not exceed ±30° 1.9 Standard: IEC/EN 60947-4-1

NC7 AC Contactor,09~620A

The NC7 series AC contactor (hereinafter referred to as “contactor”) is mainly used in the  circuit with an alternating current of 50Hz (or 60Hz), rated operational voltage up to 690V, and  rated operational current up to 620A under the usage category of AC-3/400V; this contactor is mainly used for remotely closing and breaking circuits, and can be combined with an appropriate  thermal overload relay to form a electromagnetic starter so as to protect the circuits likely to  be overloaded in operation; the contactor is well suited for frequently starting and controlling  AC motors. Standard: IEC60947-4-1

NC8 AC Contactor,06~500A

NC8 series AC contactor is applied to circuits with AC current frequency of 50 Hz or 60 Hz, rated  operationalvoltage up to 690 V and rated operational current up to 500 A. It is used for remote  making & breaking circuits, and can also be used with proper thermal overload relay together as an  electromagnetic starter to protect circuits from overload. Standard: IEC/EN 60947-4-1.

NC9 AC Contactor

1.1 Certificates: CE, UKrSEPRO; 1.2 Electrical ratings: AC50Hz, up to 1,140V, up to 1,000A; 1.3 Application: remotely makes and breaks circuit,  combined with thermal over-load relay or some protective devices to be vacuum starter; 1.4 Ambient temperature: -5℃~+40℃; 1.5 Altitude: ≤2,000m; 1.6 Mounting category: Ⅲ 1.7 Mounting conditions:  the inclination between mounting and vertical plane not exceed  ±15° 1.8 Standard: IEC/EN 60947-4-1

NCH8 Modular AC Contactor 20~63A

1.1 Electric ratings: up to 20A, 25A,  40A, 63A, 230V, 400V   AC50/60Hz; 1.2 Utilization category: AC-1, AC-7a, AC-7b; 1.3 Standard: IEC/EN 61095 CATALOG NCH8 Modular AC Contactor PDF

NCH8-M modular contactor with manual operation 16-63A

NCH8-□M series Manual Modular AC contactor (here in after referred as contactor) is mainly used in power systems with AC 50Hz/60Hz, rated operating voltage up to 400V and rated operating current up to 63A. It is used as remote or manual switch for circuit control under AC-7a and AC-7b (non-inductive load or low-inductive load/resistance furnace,domestic appliance and low-inductive load of similar applications) application category. The contactor shall not be used for breaking short-circuit current, therefore it should be used with a proper short-circuit protection device. CATALOG EN NCH8-□M PDF

NCK3 Definite Purpose Contactor 20~90A

1.1 Certificates: UL; 1.2 Application: HVACR; 1.3 Utilization category: AC-1, AC-8a; 1.4 Rated insulation voltage: 630V; 1.5 Standard: UL508 CATALOG NCK3 Definite Purpose Contactor 20~90A PDF

NCK5 Definite Purpose Contactor 20~40A

1.1 Product certification: UL, CSA 1.2 Application: HVACR 1.3 Usage category: AC-1, AC-8a 1.4 Rated insulation voltage Ui: 630V 1.5 Applicable standard: UL/CSA 60947-4-1 CATALOG NCK5 Definite Purpose Contactor 20~40A PDF

ND16 Indicator Light

1. General Degree of protection: IP65,IP40,IP20(Buzzer); Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃, the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relative humidity is up to 90%. As for dews, which contingently appear due to change of temperature, special steps should be taken. 2.4 Pollution degree: 3 2.5 Overvoltage category: Ⅲ 2.6 Tightening torque is 0.8~1.2N·m for the cable terminals, and 1.5~1.8N·m for the fixing nut. Cross section of the cable connection is 0.5~2.5mm2. CATALOG ND16 Indicator Light PDF

ND9 Indicator Light

ND9 Indicator Light 1. General 1.1 Electric ratings: 230V, AC50/60Hz; 1.2 Rated insulation voltage Ui: 500V; 1.3 Protection grade: IP20 1.4 Rated operational current: ≤20mA 1.5 Life: LED≥30000h; 1.6 Standard: IEC/EN 60947-5-1 2. Operating Conditions 2.1 Ambient temperature: -5℃~+40℃, average temperature in 24 hours not exceed +35℃; 2.2 Altitude: ≤ 2000m; 2.3 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20℃. Special measures should be taken to occurrence of dews; 2.4 Mounting category: Ⅱ, Ⅲ; 2.5 Pollution grade: Ⅱ; 2.6 Mounting mode: TH35-7.5 standard rail, inclination between mounting and vertical plane not exceed 5° 3. Wirng 2 Cross section area of the conductor is 1.0mm , and tightening torque should be 0.8N•m CATALOG ND9 Indicator Light PDF

NDK Control Transformer

1.1 Frequency: AC 50Hz/60Hz; 1.2 Application: for control power supply of apparatus, partial illumination and indicator light of     machine tool and other mechanic equipments. 1.3 Standard: Q/ZT258.

NFW1

Application: for making and breaking load current and short-circuit breaking current in 12kV AC50Hz power system. Standards: IEC 60265-1 Features:  1.High breaking capacity. 2.Safe and reliable operation. 3.Maintenance-free. 4.Flexible installation. 5.With automation distribution interfac

NFZ77

Application: for making and breaking rated current and overload current, protecting the equipments from phase-loss fault in 35kV AC50Hz power system. Standards: IEC 60265-1, IEC 62271-105. Features:   1.Compact design and light in weight. 2.High breaking capacity. 3.Maintenance-free. 4.Safety and reliable operation. 5.Long mechanical life.

NG7 C-GIS MV Switchgear

Application: ring network power supply or dual radiant power supply for 12~40.5kV power supply line. Standards: IEC62271-200 IEC62271-10 IEC62271-1 Parameters: 12~40.5kV Features: Adapt to operation environment High level of protection Compact structure Flexible expansion Maintenance free Operation reliability

NGC3 Low-voltage Switchgear Panel

Application: For circuit control, protection, monitoring and power distribution in power distribution system. Standards:  IEC 61439-1 Parameters: Rated insulation voltage: 690V, 1000V. Rated operational voltage: 400V, 690V. Features:   1.Protection degree: IP30, IP40, IP54 2.High accuracy and quality 3.Modular design of the components and spare parts. 4.Easy installation and dismantling. 5.Cable ways are specially designed for installation. In addition, cable fixing parts are available. 6.Each position of every unit is clearly indicated and max. 3 locks are available for locking.

NGC8 Low-voltage Switchgear Panel

Application: for circuit control, protection, monitoring and power distribution in power distribution system. Standards:IEC 60439-1 Parameters:Rated insulation voltage: 1000V. Rated operational voltage: 690V. Features:  1.Rated current up to 6300A. High impact resistance and high protection level. 2.Efficient distribution circuit configuration. A single standard panel can be installed with 48 circuits. 3.NJZ3.0D intelligent power control system adopted. 4.Maintenance-free. High safety protection performance, protection degree of the enclosure can be up to IP54. 5.Raw material is non-CFC and non-halogen, which is environment-friendly. 6.Structural design and material selection greatly pay attention to preventing the production of arc. 7.Modular design and flexible assembly.

NGG1 Low-voltage Switchgear Panel, Fixed Type

Application: For circuit control, protection, monitoring and power distribution in power distribution system. Standards:  IEC 60439 Parameters: Rated voltage: 400V. Rated current: 400-3150A. Rated short-circuit breaking current: 15-50kA. Features:   1.Protection degree: IP20~IP40. 2.High accuracy and quality of the switchgear could be ensured. 3.Modular design of the components and spare parts. 4.Easy installation and dismantling. 5.Good heat dispensing capability. 6.With a complete earthing protection system.

NH2 Switch Disconnector

1. 1 In the open position, It complies with the requirements of the isolating function. 1.2 It is designed match DZ series MCBs/RCBOs. CATALOG NH2 Switch Disconnector PDF

NH4 Switch Disconnector

1.1 In the open position, It complies with therequirements of the isolating function. 1.2 It is designed match NB series MCBs/RCBOs. CATALOG NH4 Switch Disconnector PDF

NH40 Switch Disconnector

1.1 Application NH40 series Switch-disconnector is applicable for AC 50Hz, rated voltage AC 690V and below, DC440V and below, rated current up to 3150A. In the industrial enterprise power distribution equipment,it can be used to connect and disconnect the circuit and isolate the power supply frequently, especially the 125A~630A can be used as frequent connected and broken. 1.2 Standard: IEC/EN60947-3.