NX8 Consumer Unit (Body)

1.1 Electric ratings: up to 100A, 230V, AC50/60Hz; 1.2 No. Of mounted units: 5, 8, 12, 15, 20, 24; 1.3 On-load current (A): 100/1-phase; 1.4 Protection degree: IP30; 1.5 Standard: IEC61439-3(EN60670-24) CATALOG NX8 Consumer Unit (Body) PDF

NX9 Consumer Unit

1. NX9 with hinged metal flap is designed for easy surface mounting for indoor installations. 2. The standard mounting rail is preassembled for mounting wide range of CHINT products. NX9-□: Incoming DIN-rail fitted with Switch Disconnector. NX9-□M: Incoming DIN-rail fitted with MCCB The outgoing DIN-rail is fitted with MCB, RCD, RCBO and Din-rail components to different specific requirements. 3. NX9 is designed with neutral and PE terminals for three phases circuit system. 4. NX9 is available in 6 sizes, suitable for different arrangements of components from 4 up to 20 modules. 5. Easy installation, distinct wiring zones and ample wiring space. CATALOG NX9 Consumer Unit PDF

NXA Series Air Circuit Breaker

▪ Frame size (A): 1600, 2000, 3200, 4000 ▪ Breaking capacity: N,S,H ▪ Rated operational voltage Ue (VAC): 380/400/415 ▪ Number of poles: 3P, 4P ▪ Installation method: draw-out type, fixed type ▪ Wiring type: horizontal rear connection

NXB-125 Moulded Case Circuit Breaker

Rated current: 63A, 80A, 100A, 125A; Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P); Frequency: 50Hz; Electromagnetic release type: C, D; Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A); Rated short-circuit breaking capacity(Icu): 10000A; Short-circuit breaking capacity(Ics): 7500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-125 Moulded Case Circuit Breaker PDF

NXB-125G Miniature Circuit Breaker

Rated current: 63, 80, 100(1P, 2P, 3P, 4P), 125(1P, 2P); Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P); Frequency: 50Hz; Electromagnetic release type: B, C, D; Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A); Rated short-circuit breaking capacity(Icn): 10000A; Short-circuit breaking capacity(Ics): 7500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-125G Miniature Circuit Breaker PDF

NXB-40 Miniature Circuit Breaker

Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A; Rated voltage: 240V; Frequency: 50Hz; Electromagnetic release type: C, D; Number of poles: 1P+N; Mechanical life: 20000 cycles; Electrical life: 10000 cycles; Rated short-circuit breaking capacity(Icu): 4500A; Short-circuit breaking capacity(Ics): 4500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-40 Miniature Circuit Breaker PDF  

NXB-63 Miniature Circuit Breaker

Overload protection, short circuit protection and isolation. It is widely used in building power distribution, industrial power distribution, as well as control and protection for a variety of equipment with operating current not exceeding 125A. CATALOGUE: NXB-63 Miniature circuit breaker PDF

NXB-63H Miniature Circuit Breaker

Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A,; Rated voltage: 240V ~ (1P, 1P+N), 415V ~ (2 ~ 4P, 3P+N); Frequency: 50Hz; Electromagnetic release type: B, C, D; Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P; Mechanical life: 20000 cycles; Electrical life: 10000 cycles; Rated short-circuit breaking capacity: 10000A; Short-circuit breaking capacity: 7500A; Rated impulse withstand voltage: 4kV; CATALOG NXB-63H Miniature circuit breaker PDF

NXC AC Contactor

The new NXC AC contactors feature a novel appearance and a compact structure. They are mainly used for frequent starts and control of AC motors as well as remote circuit making /breaking. They can also be combined with appropriate thermal overload relays to form electromagnetic starters. Compliant standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1.

NXHM Series Disconnector Switch

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for  the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A,  800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type

NXM Series Moulded Case Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type CATALOG NXM SERIES catalog

NXMLE Series Residual Current Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type

NXMS Series Moulded Case Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for  the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type

NXR Thermal Overload Relay

NXR thermal overload relays (hereinafter abbreviated as thermal relays) are suitable for overload and phase loss protection for uninterrupted or intermittent AC motors with AC frequency of 50 Hz/60 Hz, a voltage up to 690 V, and a current of (0.1-630)A. The thermal relays also provide temperature compensation, action indication, automatic and manual reset, stop, and testing functions. The products are characterized by stable and reliable performance. The thermal relays can be plugged into contactors or installed indepe-ndently. Compliant standards: IEC/EN 60947-4-1, IEC/EN 60947-5-1.

NXW1 Consumer Unit – Outdoor Application

1.1 Electric ratings: up to 63A, 230V,  AC50/60Hz; 1.2 No. of mounted units: 3, 5; 1.3 On-load current A: 63; 1.4 Protection degree: IP65; 1.5 Standard: IEC61439-3(EN60670-24) CATALOG NXW1 Consumer Unit (NXW1 Consumer Unit Body ) for Outdoor Application PDF

NXW5 Wall Mounting Enclosure

1.1 Function The Wall Mounting Enclosure is designed to adopt all kind of electrical switch gear & control gear assemblies. It is suitable for variety of Electrical installations in commercial & light industrial premises. It is designed for indoor & outdoor applications. 1.2 Features Made out of high quality Electro galvanized steel up  to1.6mm thickness. Removable Gland plate at the Bottom. Canopies can be fixed as optional. Also double insulation; excellent out door performance. Mounting plate made of 2mm GI steel or RAL 2000 Orange powder coated. Complies with IEC & NEMA standards. Available in Double door construction for width more than 800mm. Corner formed covers ensures better rain proof protection & aesthetic look 3 point cam lock for higher sizes ensures uniform locking over the entire length. CATALOG NXW5 Wall Mounting Enclosure PDF

NXZ(H)B – NXZ(H)M Series ATS

NXZ(H)B/NXZ(H)M Series Automatic Transfer Switching Equipment is applicable to three-phase four-wire duplicate supply grid of AC 50/60Hz, rated voltage 400V/415V and below, rated current 800A, and can switch one or several load circuits from one power source to the other to ensure the normal power supply of the load circuit. This product is applicable to industrial and commercial power use places, high-rise buildings, and residential houses. Standard:IEC 60947-1, IEC 60947-6-1.

NZ7 Automatic Transfer Switching Equipment

Applicable to the three-phase four-line two-circuit power supply network with an AC power frequency of 50Hz, rated operational voltage of AC400V, and rated operational current of up to 630A, the NZ7 series automatic transfer switching equipment can automatically connect one or several loads from one power source to another to ensure the normal power supply of the load circuit. This product is applicable to the important places such as industrial, commercial, and storied buildings, and residential houses. Certificate: KEMA Execution standard: IEC/EN 60947-6-1

NZB379 Motor Intelligent Control and Protection Device

Applications: for 380V power distribution system of large-scale industrial enterprises, universities ,hospitals and research institutes , real-time monitoring and auto-switching of passive compensation cabinet to ensure qualified power factor. Standard:    IEC 60255-1, IEC 60870-1 Ratings:     380Vac Features:    1.Advanced DSP core hardware platform with 8-way switching data input. 2.3-phase current and voltage measurement ,calculation of active power ,passive power, power factor and kilowatt-hour , and alarming when out of range. 3.Calculating and recording functions. 4.RS485 communication interface and Mod Bus RTU communication protocol.

NZB6 Series Protection and Management Device

Applications: in 3-phase power system of petroleum, chemical, mechanical, textile and refining fields , monitoring ,measuring ,protecting and control of 380V motor. Standard:    IEC 60255-1, IEC 60870-1 Ratings:     380Vac Features:    1.Advanced 32-bit DSP dual-core CPU hardware platform to ensure accurate and  reliable control of capacitor switching. 2.Measuring, analyzing and compensation functions. 3.Abnormal switching or fault recording function. 4.Strong anti-interference ability to ensure the system stability and  reliability under 2000V or less impulse.

NZK1-32 Change-over Switch

1.1 Certificates: KEMA; 1.2 Electric ratings: AC 50/60Hz; rated voltage up to 250V, rated current 32A; 1.3 Standard: IEC60669-1 CATALOG P075-P076 NZK1 PDF

NZK2-32 Change-over Switch

1.1 Certificates: KEMA; 1.2 Electric ratings: AC 50/60Hz; rated voltage up to 250V, rated current 32A; 1.3 Standard: IEC60669-1 CATALOG NZK2-32 Change-over Switch PDF

NZK329 Power Factor Intelligent Measurement

Applications: for 380V power distribution system of large-scale industrial enterprises, universities ,hospitals and research institutes , real-time monitoring and auto-switching of passive compensation cabinet to ensure qualified power factor. Standard:    IEC 60255-1, IEC 60870-1 Ratings:     380Vac Features:    1.Advanced DSP core hardware platform with 8-way switching data input. 2.3-phase current and voltage measurement ,calculation of active power ,passive  power, power factor and kilowatt-hour , and alarming when out of range. 3.Calculating and recording functions. 4.RS485 communication interface and Mod Bus RTU communication protocol.