Showing 211–240 of 329 results

Show sidebar

NM1B Moulded Case Circuit Breaker

NM1B series moulded case circuit breaker has a rated insulation voltage of 800V, suitable for AC 50Hz, rated operating voltage of 415V (3P), 230V / 240V (1P), and rated operating current from 10A to 125A in the distribution network circuit. It is used to distribute electrical energy and protect lines and the power supply equipment from damages such as overload and short circuit. This circuit breaker has the characteristics of small size and short flashover, and is an ideal product for users. The circuit breaker is installed vertically, and it can also be installed horizontally. The product has isolation function. Standard: IEC 60947-2。

NM8(S)L ELCB

NM8(S)L earth leakage circuit breaker is mainly suitable for circuits of AC 50Hz, with the rated voltage up to 400V, and the rated current to 630A. Its main function is to provide indirect contact protection for deadly personal electric shock. Meanwhile, it can also be used to prevent electrical fires caused by earth fault current. Besides, it protects lines from overload, short-circuit, under voltage, and for infrequent conversions

NM8(S)Moulded Case Circuit Breaker

1.1 Certificates: CE, DNV, KEMA, UKrSEPRO, EAC, RCC; 1.2 Electric ratings: AC50/60Hz, AC220V~690  16A~1600A; 1.3 Standard: IEC/EN 60947-2.

NM8N moulded case circuit breaker

1.General NM8N series moulded case circuit breaker is suitable for the circuit of AC50/60Hz, with rated voltage AC690V and below, DC system rated voltage DC1000V and below, and rated current of 16A and 1600A. It can protect circuits and electric equipment against overload, short circuit or undervoltage, and can also provide protection of overload, short circuit and under voltage for infrequent start of motor. Products have functions of power distribution protection, motor protection, residual current protection and isolation. The circuit breaker can be installed vertically, installed horizontally and can also enter the line from the bottom. Standards compliant: IEC 60947-1 general rules for low-voltage switchgear and control equipment; IEC 60947-2 low-voltage switchgear and control equipment circuit breakers; IEC 60947-3 low-voltage switchgear and control equipment switches, disconnectors and fuse combination appliances; IEC 60947-4-1 Electromechanical contactors and motor starters (including motor protectors) for low voltage switchgear and control equipment.   2.Operating conditions 2.1 Temperature: Operating and storage temperature is -40° C~+70° C; the average value within 24 hours does not exceed +35° C; when the ambient temperature is -40° C~+70° C, users need to consider derating or temperature compensation whose details can be referred to in Page 2.2 Altitude: ≤ 2000m; 2.3 Pollution grade: Grade 3; 2.4 IP grade: IP40 2.5 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40 ℃ , higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20 ℃ , special measures should be taken to occurrence of dews.

NP Series Analog Panel Meter

The models of NP series mounted panel meters are mainly NP48、NP72、NP96. (The corresponding models sold in China are 99T666, 65T666 and 51T666.) NP series square panel meters are electromagnetic type, adopting repulsive construction. The meters are consist of measuring mechanism and indicating device., with casing adopted by flame-retardant ABS engineering plastics, safe measure terminals, high-efficiency connection type, and adopted by printing dial & transparent glass cover. The whole looks beautiful and provides an open view.

NP2 Series Pushbutton

1. General Electric ratings: AC50/60Hz, AC380V/DC220V; Degree of protection: IP40; Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃,the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relative humidity is up to 90%. As for dews, which contingently appear due to change of temperature,special steps should be taken. 2.4 Pollution degree: 3 2.5 Overvoltage category: Ⅱ 2.6 Tightening torque is 0.8~1.2N·m for the cable terminals. Cross section of the cable connection is 0.5~2.5mm2, and 8mm conductor length is needed.

NP3 Series Pushbutton

1. General Electric ratings: AC50/60Hz, AC380V/DC220V; Degree of protection: IP65; Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃, the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relatice humidity is up to 90%. As for dews, which contingently appear due to change of temperature, special steps should be taken. 2.4 Pollution degree: 3 2.5 Overvoltage category: Ⅱ

NP6 Series Pushbutton

1. General Electric ratings: AC50/60Hz, AC220V/DC220V; Degree of protection: IP40; Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃, the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relative humidity is up to 90%. As for dews, which contingently appear due to change of temperature, special steps should be taken. 2.4 Pollution degree: 3 2.5 Overvoltage category: Ⅱ CATALOG NP6 Series Pushbutton PDF

NP9 Pushbutton

1. General 1.1 Electric ratings: 230V, AC50/60Hz; 1.2 Utilization category: AC-14; 1.3 Rated conventional heating current lth: 16A; 1.4 Rated operational current Ie: 6A; 1.5 Rated insulation voltage Ui: 500V; 1.6 Protection grade: IP20; 1.7 Standard: IEC/EN 60947-5-1; 2. Operating conditions 2.1 Ambient temperature: -5℃~+40℃, average temperature in 24 hours not exceed +35℃; 2.2 Altitude: ≤ 2000m; 2.3 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20℃. Special measures should be taken to occurrence of dews; 2.4 Mounting category: Ⅱ, Ⅲ; 2.5 Pollution grade: Ⅱ; 2.6 Mounting mode: TH35-7.5 standard rail, inclination between mounting and vertical plane not exceed 5°. 3. Technical data 3.1 Life (operations): a. Electric life : 100,000 b. Mechanical life : 250,000 3.2 Assembly of contact: 1NC+2NO, 2NC+1NO, 3NO, 2NC+2NO(Not available for illuminated type) 3.3 Technical data of signal lamp a. Rated operational voltage: AC/DC6.3V, AC/DC12V, AC/DC24V, AC/DC110V, AC/DC230V b. Rated operational current: ≤20mA 3.4 Life: LED≥30000h CATALOG NP9 Pushbutton PDF

NPH1 Pushbutton Box

1. General Electric ratings: AC50/60Hz, AC415V/DC250V; Degree of protection: IP65; Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃, the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relative humidity is up to 90%. As for dews, which contingently appear due to change of temperature, special steps should be taken. 2.4 Pollution grade: 3 2.5 Installation category: Ⅱ 2.6 Tightening torque is 0.8~1.2N·m for the cable terminals. Cross section of the cable connection is 0.5~2.5mm2, and 8mm conductor length is needed.

NQ2 Direct On-line Starter

1.1 NQ2 series electromagnetic starter ( "starter" for short hereinafter) applies mainly to circuit     with AC current of 50Hz (or 60Hz), rated operational voltage of 660V  and rated controlled         power up to 33kW (current up to 68A)for using to control the direct start and halt of the           electromotor to protect the motor from overload and phase failure. 1.2 The starter conforms to standards IEC/EN60947-4-1 CATALOG NQ2 Direct On-line Starter PDF

NQ3 Series DOL Electromagnetic Starter

1.1 NQ3 series electromagnetic starter ( "starter" for short hereinafter) applies mainly to circuit with AC current of 50Hz (or 60Hz), rated operational voltage of 660V and rated controlled power up to 11kW (current up to 22A) for using to control the direct start and halt of the electromotor to protect the motor from overload and phase failure. 1.2 The starter conforms to standards IEC/EN60947-4-1 CATALOG NQ3 Series DOL Electromagnetic Starter PDF

NR2 Thermal Overload Relay

1.1 Certificates: CE, KEMA, UkrSEPRO, EAC, RCC, UL; 1.2 Electric ratings: AC 50/60Hz, 690V, 0.1A~630A; 1.3 Tripping class: 10A; 1.4 Mounting version: a. Plug-in: Available for NR2-11.5, 25, 36, 93, 150; b. Independent: Available for NR2-200, 630; 1.5 Standard: IEC/EN 60947-4-1 CATALOG NR2 Thermal Overload Relay PDF

NR8 Thermal Overload Relay

Nr8 series thermal overload relay (hereinafter referred to as thermal relay) is used to provide      overload and phase failure protection for AC motors with a frequency of AC 50Hz/60Hz, a voltage of  up to 690V and a current of 0.1A~38A that operate continuously or intermittently. The thermal relay also has temperature compensation, operation indication, automatic and manual    reset and stop functions and stable and reliable performances. Standard: IEC 60947-4-1. Plug-in mounting is used between the thernal relay  and the contactor.

NRE8 Electronic Overload Relay

1.1 Certificates: CE, UKrSEPRO, UL; 1.2 Electrical ratings: AC50/60Hz, 690V; 1.3 Standards: IEC/EN 60947-4-1, UL508 CATALOG NR8 Thermal Overload Relay PDF

NS2 Motor Starter

1.1 Certificates: SEMKO, CE, UkrSEPRO, EAC, RCC, UL; 1.2 Electric ratings: AC690V, 25A, 80A; 1.3 Standard: IEC/EN 60947-2, IEC60947-4-1 CATALOG NS2 Motor Starter PDF

NTE8 Time Delay Relay

NTE8 Series time delay relay is applicable for controlling circuit @AC 50Hz/60Hz, up to 230V rated voltage or up to DC 24V rated voltage as delay element to make or break circuit according to preset time. This product meets the requirements of IEC60947-5-1.

NU6-II Low-voltage Surge Arrestor

1.1 Certificates: international certificates are under proceeding; 1.2 Number of poles: 1, 2,3, 4; 1.3 Electric ratings: 230/400V, AC50Hz; 1.4 Application: Protect electric system and on-loading electrical apparatus from thunder  and                      instantaneous over-voltage; 1.5 Standard: IEC 61643-1, EN 61643-11 CATALOG P079-P080 NU6 II PDF

NU6-III Low-voltage Surge Arrestor

1.1 Certificates: international certificates are under proceeding; 1.2 Electric ratings: Single phase power distribution and control system of AC50Hz, 230V; 1.3 Short circuit current: up to 5kA (8/20μs); 1.4 Application: Protect electric system and on-loading electrical apparatus from lightening and                    instantaneous over-voltage; 1.5 Standard:IEC61643-1, EN61643-11 CATALOG P081-P082 NU6 III PDF

NV1 Series (17.5kV,24kV), Indoor Type

Ratings: Rated voltage 17.5kV~24kV, Rated current 630A~3150A, AC50HZ Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network. Standard: IEC62271-100

NV2 Series (12kV), Indoor Type

Ratings: Rated voltage 12kV, Rated current 630A~4000A, AC50HZ Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network. Standard: IEC62271-100

NVF2G Inverter

NVF2G-series inverters are high-efficiency open-loop vector inverter researched and developed independently by our company. It has the features of high starting torque (0.5 Hz, 1.5 times of rated torque), strong overload capacity, flexible and convenient operation and forward PID and reverses PID, etc.This series of inverter can be divided into mini type, general type (heavy load) and fan and water pump type (light load), with the functions of strong load adaptability, stable and reliable operation and automatic energy-saving operation, etc. This product can be widely applied to electric drive field and automation control field, such as papermaking, textile, water supply, municipal administration, food, cement, chemical industry, printing and dyeing, metallurgy, mine and plastic machinery.

NVF300M Series Inverter

NVF300M Series Mini inverter is a kind of high-performance  vector control inverter, which is independently developed by our company. It adopts advanced control strategy to achieve  a high-precision magnetic flux vector torque control, and it is characterized by high control precision, wide speed range,  large starting torque, high reliability, strong overload capacity  and flexible and convenient operation. Rich and practical speed control, torque control, process close loop control, simple PLC, swing frequency control, multi-section speed  control and other functions can meet the needs of a variety of complex high precision drive. NVF300M Series Mini inverter is divided into single-phase and three-phase general inverters, which has strong load adaptability, stable and reliable operation, automatic energy-saving operation and other functions. It can be widely applied in medical care, food, water treatment, papermaking, textile, machine tool, conveyor belt, carpentry, traffic and transportation, communication, machinery and equipment and other electric drive and automation control fields. Products are designed and tested in accordance with the international standard; user environment test is strictly simulated. Accordant standards: GB/T 12668.2-2002, IEC 61800-2.

NVW2-12Y1250-25 (12kV), Outdoor Type

Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments. Standards: IEC 62271-100 Parameters:   Rated voltage: 12kV. Rated current: 630-1250A. Rated short-circuit breaking current: 20kA,25kA. Features:         1.Compact design and light in weight. 2.Enclosed construction can realize anti-dust and anti-moisture. 3.Maintenance-free. 4.Both manual and electric power operation and remote control.

NVW5 (12kV), Outdoor Type

Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments. Standards: IEC 62271-100 Parameters:    Rated voltage: 12kV. Rated current: 630A. Rated short-circuit breaking current: 20kA. Features:         1.Compact design and light in weight. 2.Enclosed construction filled with SF6 gas can realize anti-dust and anti-moisture. 3.Maintenance-free

NWC1 Self-healing Shunt Capacitor

1.1 Electric ratings: ≤AC1000V; 1.2 Application: For improvement of power factor and power quality; 1.3 Standards: IEC/EN 60831-1:2014 IEC/EN 60831-2:2014. CATALOG NWC1 Catalog

NWC5 Self-healing Shunt Capacitor

1.1 Edectric ratings: ≤AC1000V. 1.2 Application: Newly developed energy-saving product for improvement of power factor and power quality; 1.3 Standards: IEC/EN 60831-1:2014 IEC/EN 60831-2:2014 CATALOG NWC5 Catalog PDF

NWC6 series dry low-voltage shunt capacitor

NWC6 series dry low-voltage shunt capacitor is suitable for power frequency AC power system with nominal voltage of 1000V and below to raise power factor, reduce line loss and improve voltage quality. It is filled with dry flame-retardant materials internally. Operative norm: IEC/EN 60831-1:2014 IEC/EN 60831-2:2014. CATALOG NWC6 Catalog PDF

NWK1-GR Series Low Voltage Reactive Compensation Controller

NWK1-GR series low voltage reactive power compensation controller adopts large dot matrix LCD screen and mobile phone menu operation mode to realize man-machine exchange. Its sampling voltage range is AC (100~800) V and operating frequency range is (45~65) Hz, which are suitable for reactive power compensation and power distribution monitoring in different regions of the world. ASIC chip is used to calculate and analyze the voltage and current collected through FFT (Fast Fourier Transform), so under a large harmonic component of power grid, the reactive power can be used as the basis of switching capacitors and combined with the power factor for switching. The capacitor capacity can be matched or switched in three phases or single phase by cycle, code or any combination of values to realize the optimal compensation effect. It is the newest smart reactive compensation controller introduced by our company. The product integrates the functions of digital power grid measurement, record and storage, as well as Chinese and English or graphic real-time display of dozens of electricity, with high power measurement accuracy under harmonic environment. Besides, it provides power quality analysis, harmonic value protection and RS485 communication transmission function. Applicable standards: JB/T9663-2013; DL/T597-1996. CATALOG NWK1-GR Catalog

NX2 Consumer Unit (Body)

1.1 Electric ratings: up to 100A, 230V,  AC50/60Hz; 1.2 No. Of  mounted units: 8, 10, 14, 18, 28, 36; 1.3 On-load current (A): 100/1-phase; 1.4 Protection degree: IP30(after installation); 1.5 Standard: IEC61439-3(EN60670-24) CATALOG NX2 Consumer Unit (Body) PDF