NZL308 Intelligent Measurement and Control Device

Applications: in 380V power distribution system, monitoring single feeder and realizing remote monitoring and alarming functions. Standard:    IEC 60255-1, IEC 60870-1 Ratings:     380Vac Features:    1.Advanced DSP core hardware platform with 11-way switching data input. 2.Digital display of motor status. 3.Standard DC4~20mA analogue output.

Optical Fiber Composite LV Power Cable (OPLC)

The manufacturing of OPLC adopts the standard of Q/EPRI 038-2011 “Technical Requirements of OPLC”,and the corresponding technical requirements can meet the standard of the enterprises. 2  Scope of application The rated power frequency voltage of the cable is 0.6/1kV or lower than this level. It is also applicable in optical fiber inserting smart grid and network integrating and so on. 3  Features The OPLC adopts the current LV cable as the main body, and successfully inserts the optical fiber unit in the edge gap of the cable. The most obvious characteristics of the OPLS are as following 4 points: Firstly, OPLC integrates the function of both optical fiber and power cable, which can avoids the repeat wiring, and reduce the cost of construction and network setting up as well. Compared to the conventional installation type, using the OPLC as the solution of smart grid user connecting into the network can save a large amount of metal, pipes, plastic materials and so on, and effectively reduces the cost to getting into the communities and end users. Secondly, the flexibility and extension of OPLC is very large. Use the OPLC coordinating with relative equipments and devices, can realize running various business at the same time in one cable, such as, IPTV, Internet connection, MMTel, speech communication, home smart wattmeter and so on. Thirdly, the mechanical performance of OPLC is also very remarkable, such as shock resistance, pressurization, and environment adapting. And complicated ambient situations have been considered into the initial research and design. The performance of the OPLC in the tension, flattening, and impact test carrying out according to the GB/T7424--E1、E3、E4 are all qualified and better than the basic requirement. Last but not least, since the service time of the OPLC is very long, the compatibility of the working temperature between optical unit and power unit is a very important problem. According to the F1 test per the method in GB/T7424, the optical properties reflected from the experiment are all qualified to the requirement in YD/T629, and the electrical properties are qualified to the standard in GB/T12706.1.

OUVR-1 Self-recovery Over-voltage and Under-voltage Protector

1.1 Preventing misoperation: Where sudden transient or temporary overvoltage occurs in the line, the protector will not generate misoperation; when the line suffers instable voltage or sudden power recovery after sudden power disruption due to loose contact or other fault, the protector will not close the circuit; 1.2 Reliable operation: Protection is characterized by inverse time lag operation with operating time≤1s; 1.3 Wide scope of voltage protection: 0~450V; in case of maximum fault voltage upon line fault, the protector itself will not be damaged; 1.4 Safer, impulse withstand voltage: 4kV (conforming to the safety standard of category Ⅲ electrical apparatus); 1.5 Condition indication: The protector has the LED to indicate the operating state, where green is normal voltage indication, and red is overvoltage or undervoltage indication; 1.6 External modular design, guiderail DIN rail mounting CATALOG OUVR-1 Self-recovery Overvoltage and Undervoltage Protector

PA/PZ666- series Single Phase Digital Ammeter, Voltmeter

●Real-time measurement and indication for the current and voltage value of the power circuit ●Extensible analog output function, current range 4~20mA, 0~20 mA ,0~10 mA selectable ●Extensible relay switch output function, upper and lower alarm output can be realized. ●Extensible RS485 communication interface,  according to MOD-BUS-RTU communication protocol,  the baud rate can be set.

PD666- series Three Phase Digital Multi-function Meter

Main functions and characteristics ●LED and LCD display function ●Measurement three phase current, voltage, active power, reactive power, power factor, frequency, import and export active energy, four quadrant reactive energy. ●RS485 communication interface, according to MODBUS-RTU communication protocol, and baud rate can be set. ●Extensible switch input function. ●Extensible analog output function, current range 4~20mA, 0~20 mA ,0~10 mA selectable ●Extensible relay switch output function, upper and lower alarm output can be realized.

Polymeric Long Rod Insulator

Application: for rated voltage up to 500kV power transmission lines supporting or suspending. Standards: IEC 61109:2008, IEC 61446-1:1997, ANSI, etc. Parameters:   Rated voltage 10kV-500kV. Features:       1.Long rod polymer insulator, polymer pin insulator, polymer post insulator, and line post insulator available. 2.Secure and reliable operation on high mechanical strength. 3.Compact design and light in weight which is convenient for transportation. 4.Good anti-vibration capability. Good anti-moisture capability. 5.Good electric performances. 6.High anti-aging performances which is perfect for utilization under conditions of high altitude. 7.Easy for maintenance. 8.KEMA Certified

Polymeric Pin Insulator

Application: for rated voltage up to 500kV power transmission lines supporting or suspending. Standards: IEC 61109:2008, IEC 61446-1:1997, ANSI, etc. Parameters:     Rated voltage up 36kV. Features:     1.Long rod polymer insulator, polymer pin insulator, polymer post insulator, and  line post insulator available. 2.Secure and reliable operation on high mechanical strength. 3.Compact design and light in weight which is convenient for transportation. 4.Good anti-vibration capability. Good anti-moisture capability. 5.Good electric performances. 6.High anti-aging performances which is perfect for utilization under conditions of high altitude. 7.Easy for maintenance. 8.KEMA Certified

Polymeric Post Insulator

Application: for rated voltage up to 500kV power transmission lines supporting or suspending. Standards: IEC 61109:2008, IEC 61446-1:1997, ANSI, etc. Parameters:     Rated voltage up to 252kV. Features:     1.Long rod polymer insulator, polymer pin insulator, polymer post insulator, and  line post insulator available. 2.Secure and reliable operation on high mechanical strength. 3.Compact design and light in weight which is convenient for transportation. 4.Good anti-vibration capability. Good anti-moisture capability. 5.Good electric performances. 6.High anti-aging performances which is perfect for utilization under conditions of high altitude. 7.Easy for maintenance. 8.KEMA Certified

Power Cable

Generally, cable model selection means to choose the appropriate cable and model.Cable model specifies the cable structure of conductor, insulation, shield, sheath etc. And rated voltage; however, the specification of cable indicates the core and section area of conductor.To ensure the cable supplied by us can operate reliably for a long time in transmission line, please read the following items fully and carefully before selection the appropriate model and specifications. 1.2 Rated voltage U0/U and power system Rated voltage of cable should be selected according to the features of power system. Table 1 is the requirements of cable to power network, most 35kV power networks adopt the grounding system of arc-quenching coil of B type; direct grounding system is for 110kV above and HV, extra HV power network.

Pre-fabricated Branch Cable

1  Brief Introduction With the development of modern construction, the complexity of building distribution systems, reliability has become a topic of growing concern and attention from customer. Especially reduce the cost of distribution system in the construction site, shorten the construction cycle, enhanced supply reliability has become the strong request from the builders, investors and the electricity sector. In order to meet the market requirement, under the guidance of the Shanghai Electric Cable Research Institute experts and construction specialists, our company absorbing advanced top technology from abroad,  successfully developed the branch cable independently.“Chint” Brand branch cable and its advanced technology, reliable quality, low price to meet the requirement of users. We sincerely welcome customers to choose "Chint" brand branch cable. 2  Main advantages of prefabricate branch cable 1. Conductor of main cable has no connector, better continuity to reduce failure point. 2. Branch connectors adopt mechanical manufacturing for whole process. 3. Good branch connector structure, small contact resistance and short manufacturing process, keep contact resistance from growing larger owing to copper wire being oxidized in air. 4. Great moisture-resistant performance with high seal-ability contact. Adopt fire resistant branch cable and assure normal power supply for 90mins when during fire

PS(Q)666 Digital Wattmeter,Varmeter

Function: measure and display the single/three phase active power、reactive power in the electric lines with digital direct reading method. Both 3 phase 3 wire and 3 phase 4 wire signal input method are allowed.

PS(Q)7777 Digital Wattmeter,Varmeter

Function: measure and display the single/three phase active power、reactive power in the electric lines with digital direct reading method. Both 3 phase 3 wire and 3 phase 4 wire signal input method are allowed. There are programmable keys on the panel, which can program and set parameters including transformer rate、upper and lower limit alarm value、communication address of the meter、communication baud rate、transmitting output method、transmitting output range, etc.

Reactor

Application: It is suitable for substation and power plant, which is parallel connection in power system. It is mainly used to compensate capacitor current, reduce transmission lossand suppress the lift and capacitive operation of light load, improve system stability and prevent abnormal voltage generation. Standards: IEC 60076-6 Parameters: up to 500kV Features: Low-noise. Low losses. Compact structure.

RT28 Fuse Disconnector

RT28 Fuse Disconnector 1.Electric ratings: AC380V/500V, up to 125A; 2.Application: for protection of power distribution apparatus against over-load and short circuit; 3.The fusing indication device (code "X") of the fuse disconnector  is composed of Neon lamp and resistance; 4.Standard: IEC 60269.

RT29 Cylinder Cap Fuse

RT29 Cylinder Cap Fuse 1. Electric ratings: AC500V, up to 125A; 2. Application: for protection of  power distribution apparatus against over-load and short circuit; 3. The combination of the fuse with impinger and fuse type disconnector can be used for phase-failure protection of motors. Time delay fuse (aM) can be used for  protection of motor starting; 4. standard: IEC 60269.

RT36 Kinfe Contact Fuse Protector

RT36 Kinfe Contact Fuse Protector 1.Electric ratings: AC690V, up to 1000A; 2.Application: For protection of  electric apparatus against over-load and short circuit; 3.Features: Compact design, light weight, low power consumption and high breaking capacity; 4.Standard: IEC 60269.

S9 (Shunt Release for NB1, NBH8, NB1L, NBH8LE)

1.1 Remote opening of the device when a voltage is applied. 1.2 To be mounted on the left side of the MCBs/RCBOs thanks to the special pin. CATALOG P057-P058 S9 PDF

Surge Arrester Series

Application: for protecting rated voltage up to 500kV power transmission & distribution system from over-voltage. Standards:       IEC 60099-4 Parameters:     Rated voltage 0.22kV-500kV. Features:       1.3-36kV composite surge arresters KEMA certified. 2.GIS metal oxide surge arrester, composite metal oxide surge arrester and porcelain metal oxide surge arrester available. 3.Easy installation and maintenance. 4.Good sealing capability to ensure reliable operation. 5.Protection and reliability of the surge arrester have been greatly enhanced.

Surge Monitor & Discharge Counter

Monitor connected with surge arrester operating continuously in power system, measures change of leakage current on-line and recording the discharging times of surge arrester. According to the change of leakage current, the condition and abnormal condition during surge arrester operation could be clarified to avoid accident and improve the reliability of power system operation.Discharge counter connected with surge arrester in series is used torecord the discharging times of surge arrester. Features of the counter: 1.It is small in volume, light in weight and easy for installation. 2.Adopting wide-angle milliammeter, electromagnetic counter of single/double-pointer can increase the distance available for recording 3.Low residual voltage has no effect to surge arrester. 4.Stainless enclosure can increasing the capacity of anti-corrosion.

TAL

Application: for absorbing harmonic current generated by the harmonic source and restraining  harmonics in 6-35kV power system. Parameters:  Rated voltage: 6-35kV. Rated capacity: 0.3-60Mvar. Features:       1.Compact design and reliable operation. 2.Low loss. 3.Low operating temperature. 4.Flexible structure and easy for operation.

TB Screw Type Connection Terminal

It is suitable for circuits of AC 50Hz, with the rated voltage up to 600V, and rated current up to 100A, to be used for connection between the wires. Standard: IEC 60947-7-1

TBB

Application: for enhancement of power factor, lowering circuit loss and improve voltage quality  in rated voltage 1-110kV.  power distribution system. Standards: IEC 60871-1 Parameters:   Rated voltage: 1-110kV. Rated capacity: 0.3-60Mvar. Feature:           1.Compact design and reliable operation. 2.Inside- capacitors fuse for failure protection. 3.Outside capacitors with discharge circuit for over voltage relay                            protection. 4.With no- load tapping changer for capacity of the capacitor. 。

TBBFX

Application: for enhancement of power factor, lowering circuit loss and improve voltage quality of rated voltage 1-10kV. power distribution system. Standards: IEC 60871-1 Parameters:    Rated voltage: 1-10kV. Rated capacity: 0.3-20Mvar. Features:         1.Automatic control of reactive power. 2.Compact design. 3.High utilization of the capacitor. 4.Complete protection and control protection and high automation level.

TBBS

TBBS substation type auto-switched high-voltage shunt capacitor installation is usually installed besides 10kV or 6kV system of the substation. The equipment can effectively increase the power factor, reduce circuit losses, improve voltage quality and compensate reactive power. The equipment is divided to several capacitor banks, according to the load of system, with auto-switching of SF6 switch & controlling of micro-controller, we can realize auto compensating of the reactive power. Meanwhile, some protection, such as open-delta unbalance voltage, single capacitor error, short circuit, over current, over voltage, under voltage etc, are set up to make system stable and reliable.