Showing 91–120 of 329 results

Show sidebar

Growatt SPF5000TL

The Growatt SPF 3000-5000TL HVM series, ideal for Off-Grid Solar, or Grid Connected applications with full system monitoring.

Features:

  • Integrated MPPT charge controller
  • Configurable grid or solar input priority
  • Optional WIFI/ GPRS remote monitoring
  • Parallel for scalability
  • AC input available
DOWNLOAD BROCHURE

GW22-252 Outdoor AC Disconnector

Application: In 252kV power system, to separating the circuits under off-load status, set  up air electrical clearning between the tested electrical apparatuses and electrified circuit. Standards:  IEC 62271-102 Parameters: Rated voltage: 252kV. Rated current: 3150, 4000A. Rated short time withstand current, 3s: 50kA. Features:     1.With the min. phase distance and vertical length compared with similar products. 2.With high mechanical intensity and light by adoption of aluminum alloy at the conductive part. 3.Reliable operation. 4.Influence of the environment reduced with the operation mechanism and balancing spring sealed in tubes.

GW23-252 Outdoor AC Disconnector

Application: In 252kV power system, to separating the circuits under off-load status, set up security air electrical clearning between the tested electrical apparatuses and electrified circuit. Standards:  IEC 62271-102 Parameters: Rated voltage: 252kV. Rated current: 3150A. Rated short time withstand current, 3s: 50kA. Features:      1.With the min. phase distance and vertical length compared with similar products. 2.With high mechanical intensity and light by adoption of aluminum alloy at the conductive part. 3.Reliable operation. 4.Influence of the environment reduced with the operation mechanism and balancing spring sealed in tubes. 5.Increased contact range of moving and static contact. 6.Most of the components could be used on GW22-252 disconnector.

GW4 Outdoor AC Disconnector

Application: In rated voltage 40.5~252kV power system, to separating the circuits under off-load status, set  up air electrical clearning between the tested electrical apparatuses and electrified circuit. Standards:  IEC 62271-102 Parameters: Rated voltage: 40.5-252kV. Rated current: 1250-4000A. Rated short time withstand current, 3s: 50kA. Features:     1.Outstanding performances and reliable operation. 2.Free  maintenance due to its stable contact pressure and self-cleaning capability. 3.High anticorrosion capability. 4.Easy installation and adjustment.

H-Class Impregnated Insulated Dry-type Transformer

Application: for power distribution system and industrial enterprises, etc. Standards: IEC 60076-11 Parameters:   Rated Voltage: 10kV. Rated Capacity: 200-2500kVA. Features:       1.High security and reliability in operation. 2.Economic and efficient to reduce network loss and working cost. 3.Low noise. 4.Low partial discharge. 5.Operation in moist place with high moisture-proof capability. 6.Customized transformers are available on your requirement.

HDLRT0 Fuse for Distribution

HDLRT0 Fuse for Distribution 1.Electric ratings: AC50Hz, AC380V/DC400V, up to 1000A; 2.Application: for protection of power distribution apparatus against over-load and short circuit; 3.Standard: IEC 60269.

HH15-QA Switch Disconnector

1.1 Application Mainly used in the distributing and motor circuit which has high short-circuit current,and acted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class with drawable low voltage complete equipment. They provide safety isolation and protection against overcurrent for any low voltage electrical circuit. 1.2 Standard: IEC/EN 60947-3. 1.3 General characteristic Full-enclosed structure Unique rolling insert type contact system.

HH15-QP Switch Disconnector

1.1 Application Mainly used in the distributing and motor circui which has high short-circuit current,and acted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class  with drawable low voltage complete equipment. They provide safety isolation and protection against overcurrent for any low voltage electrical circuit. 1.2 Standard: IEC/EN 60947-3. 1.3 General characteristic Full-enclosed structure Unique rolling insert type contact system.

HH15/QSA Fuse-switch Disconnector

1.1 Application Mainly used in the distributing and motor circu which has high short-circuit current, andacted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class with drawable low voltage complete equipment. They provide safety isolation  and protection against overcurrent for any low voltage electrical circuit. 1.2 Standard: IEC/EN 60947-3. 1.3 General characteristic Full-enclosed structure Unique rolling insert type contact system.

HXGN15 Air-insulated RMU(Fixed Type)

Application: It is suitable for transformer rooms in power plants, substations and metallurgical and chemical enterprises to distribute power. It has the functions of control, protection and detection etc. Standards: IEC 62271-200 IEC 61439.2-2011 Parameters: 12-24kV 50/60Hz Features: Modular and flexible. Riveted cabinet structure. Intelligent and Compact. Environmental economy. Safe and reliable.

Intersensor

Intersensor real-time monitors environmental data including irradiance, ambient temperature, PV module temperature through various sensors. With optional sensors, such as ambient temperature sensor, wind speed sensor, and wind direction sensor more flexibility solution are achieved. Intersensor communicates via specific protocol with Chint Power data logger. Wholly system provides actual operating data analysis for a running PV module.

Interweb

The “Interweb”, a Chint Power PV power plant monitoring system, is comprised of software and configurable server. The software is a standing-alone package, and is installed under Windows OS for on-site monitoring of PV system. It is a web-based system for Internet web-access through LAN or WAN, and worked with an ultra-compact and highly efficient low power hardware. The Chint Power inverter and its peripherals are connected to Interweb via RS485 interface. Interweb records system operation data, fault messages, historical data, and etc. Configuration tools are available for flexible system management. Various charts and diagrams are provided by Interweb for yield report and analysis; the fault notifications are sent through email and/or SMS.

JCUK Connection Terminal

JCUK Connection Terminal 1. Electric ratings: Voltgae up to 690V; 2. Rated cross section area of conductor: 150mm2. 3. Standard: IEC60947-7-1

JD-5 Integrated Protector

JD-5  Integrated Protector (hereinafter referred to as protector) is applicable for overload and phase-failure protection of AC motor @ A.C.50Hz, less than AC690V rated insulation voltage and 0.5A~400A rated operating current for its continuous working or discontinuous working. Protector and AC contactor are generally used cooperatively. This product meets the requirements of IEC 60947- 4-1.

JD-5A Integrated Motor Protector

JD-5A Integrated Motor Protector (hereinafter referred to as protector) is applicable for overload, phase-failure and three-phase current unbalance protection of AC motor @ A.C.50Hz, less than AC690V rated insulation voltage and 1A~400A rated operating current for its continuous working or discontinuous working. Protector and AC contactor are generally used cooperatively. This product meets the requirements of IEC 60947-4-1.

JD-5E Integrated Motor Protector

JD-5E Integrated Motor Protector is applicable to overload and phase failure protection of AC motor working for a long time or discontinuously with AC 50Hz, rated insulation voltage AC690V and rated working current 1A-400A. The protector is usually matched with the AC contactor for use. It conforms to IEC 60947-4-1 standards.

JD-8 Integrated Motor Protector

JD-8 Integrated Motor Protector is mainly applicable to fault protection of overload and phase failure of low-voltage three-phase AC asynchronous motor in electric power system with AC frequency 50Hz and rated insulation voltage less than 690V. The protector is usually matched with the contactor in AC motor loop circuit for use. It conforms to IEC 60947-4-1 standards.

JDCF-66~132 Series Voltage Transformer

Application: for power, voltage measurement and relay protection in voltage up to 132kV AC 50Hz power system. Standards: IEC 60044-2 Ratings:   33kV-132kV Features:  1.Reliable operation. 2.Reliable insulation capability. 3.High measurement accuracy. 4.Maintenance-free. 5.Reliable sealing performance.

JDQXF-110 SF6 Voltage Transformer

Application: for power, voltage measurement and relay protection in voltage up to 126kV AC 50Hz power system. Standards: IEC 60044-2 Ratings:   110kV-132kV Features:       1.Reliable operation. 2.Reliable insulation capability. 3.High measurement accuracy. 4.Maintenance-free. 5.Reliable sealing performance

JDZXW-20 Voltage Transformer

Application: for power, voltage measurement and relay protection in  voltage up to 35kV 50/60Hz power system. Standards: IEC 60044-2 Ratings:   20kV Features:  1.Reliable operation. 2.Reliable insulation capability. 3.High measurement accuracy. 4.Maintenance-free. 5.Reliable seal performance

JDZXW9-35 Voltage Transformer

Application: for power, voltage measurement and relay protection in  voltage up to 35kV 50/60Hz power system. Standards: IEC 60044-2 Ratings:   35kV Features:  1.Reliable operation. 2.Reliable insulation capability. 3.High measurement accuracy. 4.Maintenance-free. 5.Reliable seal performance

JKF8 Intelligent Low-Voltage Reactive Power Compensation Controller

JKF8 Intelligent Low-Voltage Reactive Power Compensation Controller (hereinafter referred to as 'controller' ) is a dedicated controller which can make compensations for the reactive power of low voltage distribution system. CATALOG JKF8 Catalog

JLSZV77-10 Combined Transformer

Application: for active/reactive power measurement in voltage upto 35kV 50Hz AC power system. Standards: IEC 60044-3 Ratings:   10kV, 35kV Features:  1.Reliable operation and high measurement accuracy. 2.Easy installation. 3.Maintenance-free

JN15

Application: in 12, 24kV power system for HV busbars. Standards: IEC 62271-102 Parameters:  1.Rated voltage: 12, 24kV. 2.Rated short-time withstand current: 31.5-40kA.

JQX-10F Miniature Power Relay

1. 10A switching current 2. Various sockets available 3. Wide range of coil ratings 4. Certificate: UL, CE

JQX-13F Miniature High-Power Electromagnetic Relay

Contact switching capability of 10A; a complete range of AC/DC specifications; enclosed in transparent dust cover, a variety of mounting types; various sockets available; Specifications with state indicators available; Certifictaion: CE UL; models of the same type: LY2(N), HH62P(-L).

JSS48A Time Delay Relay

JSS48A Time Delay Relay is applicable for controlling circuit @ A.C.50Hz/60Hz, up to 380V rated control supply voltage and up to D.C. 240V rated control supply voltage as delay element to make/break circuit according to preset value.

JSZ3 Time Delay Relay

JSZ3 Time Delay Relay is applicable for automatic control system, such as machine automatic control, and complete equipment automatic control, etc.

JSZ6 Time Delay Relay

JSZ6 Time Delay Relay is applicable for automatic control system, such as machine tool automatic control, complete equipment automatic control. Etc.

JTX Miniature Power Relay

1. 10A switching current 2. Various sockets available 3. Wide range of coil ratings 4. Certificate: UL, CE