NM1B Moulded Case Circuit Breaker

NM1B series moulded case circuit breaker has a rated insulation voltage of 800V, suitable for AC 50Hz, rated operating voltage of 415V (3P), 230V / 240V (1P), and rated operating current from 10A to 125A in the distribution network circuit. It is used to distribute electrical energy and protect lines and the power supply equipment from damages such as overload and short circuit. This circuit breaker has the characteristics of small size and short flashover, and is an ideal product for users. The circuit breaker is installed vertically, and it can also be installed horizontally. The product has isolation function. Standard: IEC 60947-2。

NM8(S)L ELCB

NM8(S)L earth leakage circuit breaker is mainly suitable for circuits of AC 50Hz, with the rated voltage up to 400V, and the rated current to 630A. Its main function is to provide indirect contact protection for deadly personal electric shock. Meanwhile, it can also be used to prevent electrical fires caused by earth fault current. Besides, it protects lines from overload, short-circuit, under voltage, and for infrequent conversions

NM8(S)Moulded Case Circuit Breaker

1.1 Certificates: CE, DNV, KEMA, UKrSEPRO, EAC, RCC; 1.2 Electric ratings: AC50/60Hz, AC220V~690  16A~1600A; 1.3 Standard: IEC/EN 60947-2.

NM8N moulded case circuit breaker

1.General NM8N series moulded case circuit breaker is suitable for the circuit of AC50/60Hz, with rated voltage AC690V and below, DC system rated voltage DC1000V and below, and rated current of 16A and 1600A. It can protect circuits and electric equipment against overload, short circuit or undervoltage, and can also provide protection of overload, short circuit and under voltage for infrequent start of motor. Products have functions of power distribution protection, motor protection, residual current protection and isolation. The circuit breaker can be installed vertically, installed horizontally and can also enter the line from the bottom. Standards compliant: IEC 60947-1 general rules for low-voltage switchgear and control equipment; IEC 60947-2 low-voltage switchgear and control equipment circuit breakers; IEC 60947-3 low-voltage switchgear and control equipment switches, disconnectors and fuse combination appliances; IEC 60947-4-1 Electromechanical contactors and motor starters (including motor protectors) for low voltage switchgear and control equipment.   2.Operating conditions 2.1 Temperature: Operating and storage temperature is -40° C~+70° C; the average value within 24 hours does not exceed +35° C; when the ambient temperature is -40° C~+70° C, users need to consider derating or temperature compensation whose details can be referred to in Page 2.2 Altitude: ≤ 2000m; 2.3 Pollution grade: Grade 3; 2.4 IP grade: IP40 2.5 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40 ℃ , higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20 ℃ , special measures should be taken to occurrence of dews.

NP9 Pushbutton

1. General 1.1 Electric ratings: 230V, AC50/60Hz; 1.2 Utilization category: AC-14; 1.3 Rated conventional heating current lth: 16A; 1.4 Rated operational current Ie: 6A; 1.5 Rated insulation voltage Ui: 500V; 1.6 Protection grade: IP20; 1.7 Standard: IEC/EN 60947-5-1; 2. Operating conditions 2.1 Ambient temperature: -5℃~+40℃, average temperature in 24 hours not exceed +35℃; 2.2 Altitude: ≤ 2000m; 2.3 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20℃. Special measures should be taken to occurrence of dews; 2.4 Mounting category: Ⅱ, Ⅲ; 2.5 Pollution grade: Ⅱ; 2.6 Mounting mode: TH35-7.5 standard rail, inclination between mounting and vertical plane not exceed 5°. 3. Technical data 3.1 Life (operations): a. Electric life : 100,000 b. Mechanical life : 250,000 3.2 Assembly of contact: 1NC+2NO, 2NC+1NO, 3NO, 2NC+2NO(Not available for illuminated type) 3.3 Technical data of signal lamp a. Rated operational voltage: AC/DC6.3V, AC/DC12V, AC/DC24V, AC/DC110V, AC/DC230V b. Rated operational current: ≤20mA 3.4 Life: LED≥30000h CATALOG NP9 Pushbutton PDF

NU6-II Low-voltage Surge Arrestor

1.1 Certificates: international certificates are under proceeding; 1.2 Number of poles: 1, 2,3, 4; 1.3 Electric ratings: 230/400V, AC50Hz; 1.4 Application: Protect electric system and on-loading electrical apparatus from thunder  and                      instantaneous over-voltage; 1.5 Standard: IEC 61643-1, EN 61643-11 CATALOG P079-P080 NU6 II PDF

NU6-III Low-voltage Surge Arrestor

1.1 Certificates: international certificates are under proceeding; 1.2 Electric ratings: Single phase power distribution and control system of AC50Hz, 230V; 1.3 Short circuit current: up to 5kA (8/20μs); 1.4 Application: Protect electric system and on-loading electrical apparatus from lightening and                    instantaneous over-voltage; 1.5 Standard:IEC61643-1, EN61643-11 CATALOG P081-P082 NU6 III PDF

NX2 Consumer Unit (Body)

1.1 Electric ratings: up to 100A, 230V,  AC50/60Hz; 1.2 No. Of  mounted units: 8, 10, 14, 18, 28, 36; 1.3 On-load current (A): 100/1-phase; 1.4 Protection degree: IP30(after installation); 1.5 Standard: IEC61439-3(EN60670-24) CATALOG NX2 Consumer Unit (Body) PDF

NX8 Consumer Unit (Body)

1.1 Electric ratings: up to 100A, 230V, AC50/60Hz; 1.2 No. Of mounted units: 5, 8, 12, 15, 20, 24; 1.3 On-load current (A): 100/1-phase; 1.4 Protection degree: IP30; 1.5 Standard: IEC61439-3(EN60670-24) CATALOG NX8 Consumer Unit (Body) PDF

NX9 Consumer Unit

1. NX9 with hinged metal flap is designed for easy surface mounting for indoor installations. 2. The standard mounting rail is preassembled for mounting wide range of CHINT products. NX9-□: Incoming DIN-rail fitted with Switch Disconnector. NX9-□M: Incoming DIN-rail fitted with MCCB The outgoing DIN-rail is fitted with MCB, RCD, RCBO and Din-rail components to different specific requirements. 3. NX9 is designed with neutral and PE terminals for three phases circuit system. 4. NX9 is available in 6 sizes, suitable for different arrangements of components from 4 up to 20 modules. 5. Easy installation, distinct wiring zones and ample wiring space. CATALOG NX9 Consumer Unit PDF

NXB-125 Moulded Case Circuit Breaker

Rated current: 63A, 80A, 100A, 125A; Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P); Frequency: 50Hz; Electromagnetic release type: C, D; Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A); Rated short-circuit breaking capacity(Icu): 10000A; Short-circuit breaking capacity(Ics): 7500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-125 Moulded Case Circuit Breaker PDF

NXB-125G Miniature Circuit Breaker

Rated current: 63, 80, 100(1P, 2P, 3P, 4P), 125(1P, 2P); Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P); Frequency: 50Hz; Electromagnetic release type: B, C, D; Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A); Rated short-circuit breaking capacity(Icn): 10000A; Short-circuit breaking capacity(Ics): 7500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-125G Miniature Circuit Breaker PDF

NXB-40 Miniature Circuit Breaker

Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A; Rated voltage: 240V; Frequency: 50Hz; Electromagnetic release type: C, D; Number of poles: 1P+N; Mechanical life: 20000 cycles; Electrical life: 10000 cycles; Rated short-circuit breaking capacity(Icu): 4500A; Short-circuit breaking capacity(Ics): 4500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-40 Miniature Circuit Breaker PDF  

NXB-63 Miniature Circuit Breaker

Overload protection, short circuit protection and isolation. It is widely used in building power distribution, industrial power distribution, as well as control and protection for a variety of equipment with operating current not exceeding 125A. CATALOGUE: NXB-63 Miniature circuit breaker PDF

NXB-63H Miniature Circuit Breaker

Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A,; Rated voltage: 240V ~ (1P, 1P+N), 415V ~ (2 ~ 4P, 3P+N); Frequency: 50Hz; Electromagnetic release type: B, C, D; Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P; Mechanical life: 20000 cycles; Electrical life: 10000 cycles; Rated short-circuit breaking capacity: 10000A; Short-circuit breaking capacity: 7500A; Rated impulse withstand voltage: 4kV; CATALOG NXB-63H Miniature circuit breaker PDF

NXHM Series Disconnector Switch

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for  the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A,  800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type

NXM Series Moulded Case Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type CATALOG NXM SERIES catalog

NXMLE Series Residual Current Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type

NXMS Series Moulded Case Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for  the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type

NXW1 Consumer Unit – Outdoor Application

1.1 Electric ratings: up to 63A, 230V,  AC50/60Hz; 1.2 No. of mounted units: 3, 5; 1.3 On-load current A: 63; 1.4 Protection degree: IP65; 1.5 Standard: IEC61439-3(EN60670-24) CATALOG NXW1 Consumer Unit (NXW1 Consumer Unit Body ) for Outdoor Application PDF

NXW5 Wall Mounting Enclosure

1.1 Function The Wall Mounting Enclosure is designed to adopt all kind of electrical switch gear & control gear assemblies. It is suitable for variety of Electrical installations in commercial & light industrial premises. It is designed for indoor & outdoor applications. 1.2 Features Made out of high quality Electro galvanized steel up  to1.6mm thickness. Removable Gland plate at the Bottom. Canopies can be fixed as optional. Also double insulation; excellent out door performance. Mounting plate made of 2mm GI steel or RAL 2000 Orange powder coated. Complies with IEC & NEMA standards. Available in Double door construction for width more than 800mm. Corner formed covers ensures better rain proof protection & aesthetic look 3 point cam lock for higher sizes ensures uniform locking over the entire length. CATALOG NXW5 Wall Mounting Enclosure PDF

NZK1-32 Change-over Switch

1.1 Certificates: KEMA; 1.2 Electric ratings: AC 50/60Hz; rated voltage up to 250V, rated current 32A; 1.3 Standard: IEC60669-1 CATALOG P075-P076 NZK1 PDF

NZK2-32 Change-over Switch

1.1 Certificates: KEMA; 1.2 Electric ratings: AC 50/60Hz; rated voltage up to 250V, rated current 32A; 1.3 Standard: IEC60669-1 CATALOG NZK2-32 Change-over Switch PDF

OUVR-1 Self-recovery Over-voltage and Under-voltage Protector

1.1 Preventing misoperation: Where sudden transient or temporary overvoltage occurs in the line, the protector will not generate misoperation; when the line suffers instable voltage or sudden power recovery after sudden power disruption due to loose contact or other fault, the protector will not close the circuit; 1.2 Reliable operation: Protection is characterized by inverse time lag operation with operating time≤1s; 1.3 Wide scope of voltage protection: 0~450V; in case of maximum fault voltage upon line fault, the protector itself will not be damaged; 1.4 Safer, impulse withstand voltage: 4kV (conforming to the safety standard of category Ⅲ electrical apparatus); 1.5 Condition indication: The protector has the LED to indicate the operating state, where green is normal voltage indication, and red is overvoltage or undervoltage indication; 1.6 External modular design, guiderail DIN rail mounting CATALOG OUVR-1 Self-recovery Overvoltage and Undervoltage Protector