Showing 481–504 of 504 results

Show sidebar

Yanmar Diesel Generator 50Hz

KEYPOWER Yanmar series generator is powered by Yanmar engine with compact structure and simple operation and the feature of environmental friendly, high reliability and fuel efficiency. It is complian.

Yanmar Diesel Generator 50Hz

KEYPOWER Volvo series generator power by Volvo engine, comply with the most stringent environmental demands, engines keep your operation running. low noise, fuel-saving.

YBLT-3, YBLT-4 Foot Switch

The foot switch YBLT-3,4 series is suitable for alternating current 50Hz/60Hz;and the control lines of voltage to 380V,volts d.c.to 220V;as control machine tools electric,medical facility. In accordance with standard: GB/T 14048.5, IEC 60947-5-1. CATALOG YBLT-3, YBLT-4 Foot Switch PDF

YBLT-FS/1 Foot Switch

Voltage rating:AC-15 380V ; DC-13 220V; Voltage current:AC-15 0.79A ; DC-13 0.14A; Promise heating current:5A; Sheathing material:YBLT-FS/1 armor plate. CATALOG YBLT-FS 1 Foot Switch PDF

YBLT-FS/201 Foot Switch

YBLT-FS∕201 foot switches apply to the control circuit, whose alternating current is 50Hz/60Hz,voltage is 380v,direct current is 220v,as electrical control of machinery tools,armarium and so on. The normal operation of switch is on altitude, which is not exceeding 2000m,ambient temperature is -30℃~+40℃,relative air humidity is not more than 85%;up to standard:GB/T 14048.5, IEC 60947-5-1. CATALOG YBLT-FS 201 Foot Switch PDF

YBLX-10 Travel Switch

Series of YBLX-10 travel switch is suitable for AC-15 50Hz,Ue 380V,DC-13 220V, Ith 10A in electrical control circuit, using as terminal protection and travel switch for different kinds of crane, metallurgy and water equipment. CATALOG YBLX-10 Travel Switch PDG

YBLX-19 Travel Switch

Apply to AC-15 50Hz/60Hz,Ue380V,le0.79A DC-13 Ue220V le0.1A and the following electrical lines, as stroke control of motion mechanism, motion direction or speed transformation, automatic machine tool control, limiting action of motion mechanism and control the trip or procedures used. Standard: GB/T 14048.5,IEC 60947-5-1, won the Certification of CCC National mandatory product. CATALOG YBLX-19 Travel Switch PDF

YBLX-CK Travel Switch

YBLX-CK series of travel switch is applicable to electric circuit with voltage not more than AC-15 380V,50Hz/60Hz or DC-13 220V, for travel control, direction of motion or speed change of movement mechanism, automatic control of machine tool, limit action & travel or procedure control of movement mechanism. CATALOG YBLX-CK Travel Switch PDF

YBLX-K1 Travel Switch

YBLX-K1 series of travel switch is applicable to electric circuit with voltage not more than AC-15 Ue 380V,50Hz/60Hz or DC -13 Ue 220V and current not more than AC-15 Ie 0.8A or DC13 Ie 0.15A for travel control, direction of motion or speed change of movement mechanism, automatic control, motion direction or speed change of machine tool, automatic control, action limit & travel or procedure control of movement mechanism. Standard: GB/T 14048.5,IEC60947-5-1,CCC China Compulsory Product Certification. CATALOG YBLX-K1 Travel Switch PDF

YBLX-K3 Travel Switch

YBLX-K3 series of travel switch is applicable to electric circuit with voltage not more than AC-15 Ue 380V,50Hz/ 60Hz or DC-13 Ue 220V and current not more than AC-15 Ie 5A 0.8A or DC-13 Ie 0.15A for travel control, direction of motion or speed change of movement mechanism, automatic control of machine tool, action limit & travel or procedure control of movement mechanism. Standard: GB/T 14048.5, IEC60947-5-1,CCC China Compulsory Product Certification. CATALOG YBLX-K3 Travel Switch PDF

YBLX-ME Travel Switch

YBLX-ME series of travel switch is applicable to electric circuit with voltage not more than AC-15 380V,50Hz/ 60Hz or DC-13 Ue 220V and current not more than AC-15 Ie 0.8A or DC-13 Ie 0.16A as travel control, direction of motion or speed change of movement mechanism, automatic control of machine tool, limit action & travel or procedure control of movement mechanism. Standard: GB/T 14048.5,IEC60947-5-1,CCC China Compulsory Product Certification CATALOG YBLX-ME Travel Switch PDF

YBLX-P1 Travel Switch

YBLX-P1 series of travel switch is applicable to electric circuit with voltage not more than AC-15 Ue 380V,50Hz/60Hz or DC-13 Ue 220V and current not more than AC-15 Ie 0.8A or DC-13 Ie 0.15A for travel control, direction of motion or speed change of movement mechanism, automatic control of machine tool, limit action & travel or procedure control of movement mechanism. Standard: GB/T 14048.5,IEC60947-5-1,CCC China Compulsory Product Certification. CATALOG YBLX-P1 Travel Switch PDF

YBLX-WL Travel Switch

YBLX-WL travel switch (hereinafter referred to as switch) is mainly applicable to electrical circuit with AC-15 380V or DC-13 220V, 50Hz/60Hz for travel control, direction of motion or speed change of movement mechanism, automatic control of machine tool, limit action & travel or procedure control of movement mechanism. Standard: GB/T 14048.5 IEC60947-5-1. CATALOG YBLX-WL Travel Switch PDF

YBLXW-5 Microswitch

YBLX-WL travel switch (hereinafter referred to as switch) is mainly applicable to electrical circuit with AC-15 380V or DC-13 220V, 50Hz/60Hz for travel control, direction of motion or speed change of movement mechanism, automatic control of machine tool, limit action & travel or procedure control of movement mechanism. Standard: GB/T 14048.5 IEC60947-5-1. CATALOG YBLX-WL Travel Switch PDF

YBLXW-6 Microswitch

YBLXW-6 series microswitches apply to the control circuit, whose alternating current are 50Hz/60Hz,AC-15 380V,Ie0.79A;DC-13 220V,Ie0.14A.They are widely applied to the travel control, spacing protection and change the use of circuit component of all kinds of machinery equipments, which are machinery, spinning,light industry,electronic instrument and so on. The normal operation of products are on altitude, which is not exceeding 2000m,environment temperature is -5℃~+40℃; humidity is 85%(20℃);operation frequency is 20 times every minute, level of protection is IP52. Up to standard:GB/T 14048.5,IEC 60947-5-1,acquired CCC national compulsory product certification. CATALOG YBLXW-6 Microswitch PDF

YUCHAI Diesel Generators 50Hz

KEYPOWER Yuchai Series generator is powered by Yuchai diesel engine which covers a wide power range from 50kva up to 3000kva, Yuchai is also the partner of MTU in China who manufactures 4000 series of diesel engine for MTU.

ZG1.6-1,ZG2.5-1 Series IC Card Pre-paid Gas Meter

ZG1.6-1, ZG2.5-1 Series IC card prepayment gas meter is a kind of intelligent prepaid flow meter. It applies to measure the flux of flammable material such as natural gas, liquefied petrol gas, marsh gas and gas in city’s pipeline etc. The applied pressure is from 0.5 to 20 kPa. The gas meter adopts intelligent metering control device, with immunity to magnetic field, strong confidentiality, high reliability, etc. It adopts LCD display with 8 digit. The gas meter are in compliance with the requirements of CJ/T 112-2008、class B of GB/T6968(-1997), JJG577-2005.

ZG1.6S-1,ZG2.5S-1,ZG4S-1 Series IC Card Prepayment Gas Meter

ZG1.6S-1, ZG2.5S-1 and ZG4S-1 Series IC card prepayment gas meter is a kind of intelligent prepaid flow meter. It applies to measure the flux of flammable material such as natural gas, liquefied petrol gas, marsh gas and gas in city’s pipeline etc. The applied pressure is from 0.5 to 50 kPa. And also management of prepaid can processed. The gas meter adopts intelligent measuring control device. It has advantages as follows: low power loss, resistant to interruption of magnet, inquired button, overdraft button, valve-opened button, anti-attack IC card, high reliability, strong confidential, strong capacity of anticorrosive, good appearance, accurate measurement, high sensitivity etc. It adopts LCD display with 8 digits. The gas meter are in compliance with the requirements of CJ/T 112-2008、class B of GB/T6968(-1997), JJG577-2005.

ZN63A-12(VS1) (12kV), Indoor Type

Application: in 12kV power distribution system for control and protection. Standards: IEC 62271-100 Parameters:   Rated voltage: 12kV. Rated current: 630-5000A. Rated short-circuit breaking current: 20-50kA. Features:         1.Advanced arc-extinguishing mode adopted. 2.High insulation level and peak withstand current capacity. 3.Impact and vibration reduced, Less maintenance. 4.Mechanical endurance up to 20,000 times.

ZN85-40.5 (40.5kV), Indoor Type

Application: in 40.5kV power distribution system for control and protection. Standards: IEC 62271-100 Parameters:    Rated voltage: 40.5kV. Rated current: 630-2000A. Rated short-circuit breaking current: 20-31.5kA. Features:         1.High insulation level and breaking capacity. 2.Compact and modular deign. 3.Less maintenance. 4.High operation endurance. 5.Applicable to various working conditions

ZT-G1.6S, ZT-G2.5S, ZT-G4S Steel Case Gas Meter

ZT-G1.6S,ZT-G2.5S and ZT-G4S diaphragm gas meter are volumetric diaphragm gas meters(hereinafter referred as “diaphragm gas meters”, which are mainly used in measuring the volume of natural gas, city pipe gas, liquid gas, marsh gas and other gas with working pressure of 5mbar~0.5bar. The gas meter has the following characteristics: elegant appearance, wide measuring range, stable metrology, high sensitivity, good reliability, long operation life, anti-tampering ability and good corrosion resistance. The gas meters are in compliance with EN 1359:1998/A1:2006、2004/22/EC(MID)、OIML R31:1995、OIML R137-2006、EEC 71/318、Dutch national approval Class 1 requirements.

ZW32-12 (12kV),Outdoor Type

Ratings: voltage up to 10kV, current 630A, AC50Hz. Application: for making & breaking load current, overload current and short-circuit protection of electric systems and equipments. Standard: IEC62271-100

ZW7-40.5 (40.5kV), Outdoor Type

Application: in 40.5kV power system, for making and breaking load current, overload current and short circuit protection. Standards: IEC 62271-100 Parameters:   Rated voltage: 40.5kV. Rated current: 1250~2000A. Rated short-circuit breaking current: 20kA, 25kA, 31.5kA. Features:         1.Simple construction and easy installation. 2.High insulation level and waterproof. 3.Both spring and magnetic operation mechanism available. 4.Internal current transformers can realize multiple transformation ratio output, high secondary output.

ZW8-12(Z) (12kV), Outdoor Type

Application: in 12kV power distribution system for control and protection. Standards: IEC 62271-100 Parameters:    Rated voltage: 12kV. Rated current: 630-1000A. Rated short-circuit breaking current: 12.5-20kA. Features:          1.Low loss for the control unit. 2.Anti-dust and anti-moisture. 3.Back-up battery could be installed to ensure the normal work of 12 hours after break. 4.The programmable interface and software could facilitate the utilization. 5.Various telecommunication modes are available. 6.Remotely controlled through DMS system telecommunication