Showing 331–360 of 504 results

Show sidebar

NTE8 Time Delay Relay

NTE8 Series time delay relay is applicable for controlling circuit @AC 50Hz/60Hz, up to 230V rated voltage or up to DC 24V rated voltage as delay element to make or break circuit according to preset time. This product meets the requirements of IEC60947-5-1.

NU6-II Low-voltage Surge Arrestor

1.1 Certificates: international certificates are under proceeding; 1.2 Number of poles: 1, 2,3, 4; 1.3 Electric ratings: 230/400V, AC50Hz; 1.4 Application: Protect electric system and on-loading electrical apparatus from thunder  and                      instantaneous over-voltage; 1.5 Standard: IEC 61643-1, EN 61643-11 CATALOG P079-P080 NU6 II PDF

NU6-III Low-voltage Surge Arrestor

1.1 Certificates: international certificates are under proceeding; 1.2 Electric ratings: Single phase power distribution and control system of AC50Hz, 230V; 1.3 Short circuit current: up to 5kA (8/20μs); 1.4 Application: Protect electric system and on-loading electrical apparatus from lightening and                    instantaneous over-voltage; 1.5 Standard:IEC61643-1, EN61643-11 CATALOG P081-P082 NU6 III PDF

NV1 Series (17.5kV,24kV), Indoor Type

Ratings: Rated voltage 17.5kV~24kV, Rated current 630A~3150A, AC50HZ Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network. Standard: IEC62271-100

NV2 Series (12kV), Indoor Type

Ratings: Rated voltage 12kV, Rated current 630A~4000A, AC50HZ Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network. Standard: IEC62271-100

NVF2G Inverter

NVF2G-series inverters are high-efficiency open-loop vector inverter researched and developed independently by our company. It has the features of high starting torque (0.5 Hz, 1.5 times of rated torque), strong overload capacity, flexible and convenient operation and forward PID and reverses PID, etc.This series of inverter can be divided into mini type, general type (heavy load) and fan and water pump type (light load), with the functions of strong load adaptability, stable and reliable operation and automatic energy-saving operation, etc. This product can be widely applied to electric drive field and automation control field, such as papermaking, textile, water supply, municipal administration, food, cement, chemical industry, printing and dyeing, metallurgy, mine and plastic machinery.

NVF300M Series Inverter

NVF300M Series Mini inverter is a kind of high-performance  vector control inverter, which is independently developed by our company. It adopts advanced control strategy to achieve  a high-precision magnetic flux vector torque control, and it is characterized by high control precision, wide speed range,  large starting torque, high reliability, strong overload capacity  and flexible and convenient operation. Rich and practical speed control, torque control, process close loop control, simple PLC, swing frequency control, multi-section speed  control and other functions can meet the needs of a variety of complex high precision drive. NVF300M Series Mini inverter is divided into single-phase and three-phase general inverters, which has strong load adaptability, stable and reliable operation, automatic energy-saving operation and other functions. It can be widely applied in medical care, food, water treatment, papermaking, textile, machine tool, conveyor belt, carpentry, traffic and transportation, communication, machinery and equipment and other electric drive and automation control fields. Products are designed and tested in accordance with the international standard; user environment test is strictly simulated. Accordant standards: GB/T 12668.2-2002, IEC 61800-2.

NVW2-12Y1250-25 (12kV), Outdoor Type

Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments. Standards: IEC 62271-100 Parameters:   Rated voltage: 12kV. Rated current: 630-1250A. Rated short-circuit breaking current: 20kA,25kA. Features:         1.Compact design and light in weight. 2.Enclosed construction can realize anti-dust and anti-moisture. 3.Maintenance-free. 4.Both manual and electric power operation and remote control.

NVW5 (12kV), Outdoor Type

Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments. Standards: IEC 62271-100 Parameters:    Rated voltage: 12kV. Rated current: 630A. Rated short-circuit breaking current: 20kA. Features:         1.Compact design and light in weight. 2.Enclosed construction filled with SF6 gas can realize anti-dust and anti-moisture. 3.Maintenance-free

NWC1 Self-healing Shunt Capacitor

1.1 Electric ratings: ≤AC1000V; 1.2 Application: For improvement of power factor and power quality; 1.3 Standards: IEC/EN 60831-1:2014 IEC/EN 60831-2:2014. CATALOG NWC1 Catalog

NWC5 Self-healing Shunt Capacitor

1.1 Edectric ratings: ≤AC1000V. 1.2 Application: Newly developed energy-saving product for improvement of power factor and power quality; 1.3 Standards: IEC/EN 60831-1:2014 IEC/EN 60831-2:2014 CATALOG NWC5 Catalog PDF

NWC6 series dry low-voltage shunt capacitor

NWC6 series dry low-voltage shunt capacitor is suitable for power frequency AC power system with nominal voltage of 1000V and below to raise power factor, reduce line loss and improve voltage quality. It is filled with dry flame-retardant materials internally. Operative norm: IEC/EN 60831-1:2014 IEC/EN 60831-2:2014. CATALOG NWC6 Catalog PDF

NWK1-GR Series Low Voltage Reactive Compensation Controller

NWK1-GR series low voltage reactive power compensation controller adopts large dot matrix LCD screen and mobile phone menu operation mode to realize man-machine exchange. Its sampling voltage range is AC (100~800) V and operating frequency range is (45~65) Hz, which are suitable for reactive power compensation and power distribution monitoring in different regions of the world. ASIC chip is used to calculate and analyze the voltage and current collected through FFT (Fast Fourier Transform), so under a large harmonic component of power grid, the reactive power can be used as the basis of switching capacitors and combined with the power factor for switching. The capacitor capacity can be matched or switched in three phases or single phase by cycle, code or any combination of values to realize the optimal compensation effect. It is the newest smart reactive compensation controller introduced by our company. The product integrates the functions of digital power grid measurement, record and storage, as well as Chinese and English or graphic real-time display of dozens of electricity, with high power measurement accuracy under harmonic environment. Besides, it provides power quality analysis, harmonic value protection and RS485 communication transmission function. Applicable standards: JB/T9663-2013; DL/T597-1996. CATALOG NWK1-GR Catalog

NX2 Consumer Unit (Body)

1.1 Electric ratings: up to 100A, 230V,  AC50/60Hz; 1.2 No. Of  mounted units: 8, 10, 14, 18, 28, 36; 1.3 On-load current (A): 100/1-phase; 1.4 Protection degree: IP30(after installation); 1.5 Standard: IEC61439-3(EN60670-24) CATALOG NX2 Consumer Unit (Body) PDF

NX8 Consumer Unit (Body)

1.1 Electric ratings: up to 100A, 230V, AC50/60Hz; 1.2 No. Of mounted units: 5, 8, 12, 15, 20, 24; 1.3 On-load current (A): 100/1-phase; 1.4 Protection degree: IP30; 1.5 Standard: IEC61439-3(EN60670-24) CATALOG NX8 Consumer Unit (Body) PDF

NX9 Consumer Unit

1. NX9 with hinged metal flap is designed for easy surface mounting for indoor installations. 2. The standard mounting rail is preassembled for mounting wide range of CHINT products. NX9-□: Incoming DIN-rail fitted with Switch Disconnector. NX9-□M: Incoming DIN-rail fitted with MCCB The outgoing DIN-rail is fitted with MCB, RCD, RCBO and Din-rail components to different specific requirements. 3. NX9 is designed with neutral and PE terminals for three phases circuit system. 4. NX9 is available in 6 sizes, suitable for different arrangements of components from 4 up to 20 modules. 5. Easy installation, distinct wiring zones and ample wiring space. CATALOG NX9 Consumer Unit PDF

NXA Series Air Circuit Breaker

▪ Frame size (A): 1600, 2000, 3200, 4000 ▪ Breaking capacity: N,S,H ▪ Rated operational voltage Ue (VAC): 380/400/415 ▪ Number of poles: 3P, 4P ▪ Installation method: draw-out type, fixed type ▪ Wiring type: horizontal rear connection

NXB-125 Moulded Case Circuit Breaker

Rated current: 63A, 80A, 100A, 125A; Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P); Frequency: 50Hz; Electromagnetic release type: C, D; Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A); Rated short-circuit breaking capacity(Icu): 10000A; Short-circuit breaking capacity(Ics): 7500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-125 Moulded Case Circuit Breaker PDF

NXB-125G Miniature Circuit Breaker

Rated current: 63, 80, 100(1P, 2P, 3P, 4P), 125(1P, 2P); Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P); Frequency: 50Hz; Electromagnetic release type: B, C, D; Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A); Rated short-circuit breaking capacity(Icn): 10000A; Short-circuit breaking capacity(Ics): 7500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-125G Miniature Circuit Breaker PDF

NXB-40 Miniature Circuit Breaker

Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A; Rated voltage: 240V; Frequency: 50Hz; Electromagnetic release type: C, D; Number of poles: 1P+N; Mechanical life: 20000 cycles; Electrical life: 10000 cycles; Rated short-circuit breaking capacity(Icu): 4500A; Short-circuit breaking capacity(Ics): 4500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-40 Miniature Circuit Breaker PDF  

NXB-63 Miniature Circuit Breaker

Overload protection, short circuit protection and isolation. It is widely used in building power distribution, industrial power distribution, as well as control and protection for a variety of equipment with operating current not exceeding 125A. CATALOGUE: NXB-63 Miniature circuit breaker PDF

NXB-63H Miniature Circuit Breaker

Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A,; Rated voltage: 240V ~ (1P, 1P+N), 415V ~ (2 ~ 4P, 3P+N); Frequency: 50Hz; Electromagnetic release type: B, C, D; Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P; Mechanical life: 20000 cycles; Electrical life: 10000 cycles; Rated short-circuit breaking capacity: 10000A; Short-circuit breaking capacity: 7500A; Rated impulse withstand voltage: 4kV; CATALOG NXB-63H Miniature circuit breaker PDF

NXC AC Contactor

The new NXC AC contactors feature a novel appearance and a compact structure. They are mainly used for frequent starts and control of AC motors as well as remote circuit making /breaking. They can also be combined with appropriate thermal overload relays to form electromagnetic starters. Compliant standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1.