166(355~370)AstroTwins_CHSM60M(DGT)F-BH
Power range:355W~370W
Max. system voltage:1500 VDC
Dimention:1791 x 1052 x 30 mm / 70.51 x 41.42 x 1.18 inch
Frame thickness:30 mm / 1.18 inch
Glass thickness:2.0 mm / 0.08 inch
Cable length:Portrait: 350 mm (13.78 inch) Landscape: 1200 mm (47.24 inch)
SKU: TWN825565
Categories: Astro Twins, Electrical Products, New Energy, PV Module
Tags: AstroTwins, New Energy, PV Module, solar panel
Related products
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
CATALOG
NB1-63DC DC Miniature Circuit Breaker PDF
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection
1.1 Selection
Rated residual operating current
I∆n = 30 mA: additional protection in the case of direct contact.
Tripping class
AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big
length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.2 Approvals and certificates
CATALOG
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection PDF
eB Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT
systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-20In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
eB Miniature Circuit Breaker PDF
HDLRT0 Fuse for Distribution
HDLRT0 Fuse for Distribution
1.Electric ratings: AC50Hz, AC380V/DC400V, up to 1000A;
2.Application: for protection of power distribution apparatus against over-load and short circuit;
3.Standard: IEC 60269.
DZ158 Moulded Case Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
DZ158 Moulded Case Circuit Breaker(DC type)