CPS SC100kW
The CPS SC100KT grid-tied PV inverter is designed for flexible use in different types of commercial rooftops and unility. It features isolation output transformer, low loss magnetic materials, advanced MPPT control and variable structure SVPWM control to minimize power loss and achieve high efficiency at all load levels. Enhanced DSP control, comprehensive protection functions and advanced thermal design enable the whole system with high reliability.
SKU: COM83556
Categories: Commercial, Electrical Products, Grid-tied PV Inverter, New Energy, Solar Inverters
Tags: commercial, Grid-tied PV Inverter, New Energy
Related products
NXB-125G Miniature Circuit Breaker
Rated current: 63, 80, 100(1P, 2P, 3P, 4P), 125(1P, 2P);
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: B, C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icn): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125G Miniature Circuit Breaker PDF
CPS SCE1.5-4.6kW Series
SCE series PV inverters are suitable for various residential and commercial rooftop PV systems. With the features of concise design and high reliability of the former generation, SCE series PV inverters offer an improved performance on the conversion efficiency reaching up to 97.5%. The internal design offering now standard embedded DC switch and RS485 communication making of the SCE series a safe and flexible product for customers.
NB1-63G Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currentsprotection of circuits against overload currents,switch,isolation,
NB1-63G circuit-breakers are used in domestic installation,as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point consideredshort-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,
Network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrus current.
CATALOG
NB1-63G Miniature Circuit Breaker PDF
CPS SC20kWUS
The CPS SC20KTL-DO/US-480 grid-tied PV inverter is a tranformerless, three phase product designed for the North America market in compliance with UL and CSA standards. Patented 3-level control algorithm and thermal design provide 97.3% maximum efficiency. CPS SC20KTL-DO/US-480 features small size, light weight and high power density. Multi flexible mounting modes make installation and maintenance easy and quick. The enclosure of the inverter is rated NEMA 3R (IP65) for general purpose outdoor applications. Enhanced DSP control, comprehensive protection functions and advanced thermal design enable a high reliability product with optional warranties up to 20 years.
NBH8 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),
short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
CATALOG
NBH8 Miniature Circuit Breaker PDF
HDLRT0 Fuse for Distribution
HDLRT0 Fuse for Distribution
1.Electric ratings: AC50Hz, AC380V/DC400V, up to 1000A;
2.Application: for protection of power distribution apparatus against over-load and short circuit;
3.Standard: IEC 60269.
NB1-63 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-14In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.