Reactor
Application: It is suitable for substation and power plant, which is parallel connection in power system. It is mainly used to compensate capacitor current, reduce transmission lossand suppress the lift and capacitive operation of light load, improve system stability and prevent abnormal voltage generation.
Standards: IEC 60076-6
Parameters: up to 500kV
Features: Low-noise.
Low losses.
Compact structure.
SKU: REA345
Categories: Electrical Products, Oil-immersed Transformer (up to 750KV), Power T&D, Power Transformer
Tags: Oil-immersed Shunt Reactor(up to 500kV), Power T&D, Power Transformer, Reactor
Related products
NXB-125 Moulded Case Circuit Breaker
Rated current: 63A, 80A, 100A, 125A;
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icu): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125 Moulded Case Circuit Breaker PDF
NXB-40 Miniature Circuit Breaker
Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A;
Rated voltage: 240V;
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P+N;
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles;
Rated short-circuit breaking capacity(Icu): 4500A;
Short-circuit breaking capacity(Ics): 4500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-40 Miniature Circuit Breaker PDF
HDLRT0 Fuse for Distribution
HDLRT0 Fuse for Distribution
1.Electric ratings: AC50Hz, AC380V/DC400V, up to 1000A;
2.Application: for protection of power distribution apparatus against over-load and short circuit;
3.Standard: IEC 60269.
NL210 Residual Current Operated Circuit Breaker without Over-current Protection
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 Selection
Detectable wave form
Type B
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.
Tripping sensitivity
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;
300mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping (without time-delay).
1.3 Approvals and certificates CE, KEMA
1.4 Add-on devices
AX-5 auxiliary contacts
TC-1 terminal cover
CATALOG
NL210 Residual Current Operated Circuit Breaker without Over-current Protection PDF
NL1 Residual Current Operated Circuit Breaker without Over-current Protection (Magnetic)
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 Selection
Detectable wave form
AC class
Tripping is ensured for slowly increasing sinusoidal AC residual currents.
A class
Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.
S, G/SI class
Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges.
With the impact of 8/20us surge 3000A, this high immunity
RCCB will still be in stable status.
CATALOG