NKG3 Time Switch
NKG3 time switch (hereinafter referred to as time switch) is used in automatic control circuits with a frequency of AC 50Hz(or 60Hz), a rated control supply voltage of up to 220V and a rated operational current of 3A to provide timed on-off control for street lamps, advertising lamps and similar equipment.
SKU: ELC7661
Categories: Electrical Products, Low Voltage Electric, Relays, Time Relay
Tags: Low voltage electric, Relay, Time Relay
Related products
NXB-40 Miniature Circuit Breaker
Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A;
Rated voltage: 240V;
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P+N;
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles;
Rated short-circuit breaking capacity(Icu): 4500A;
Short-circuit breaking capacity(Ics): 4500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-40 Miniature Circuit Breaker PDF
NB3LE Residual Current Operated Circuit Breaker with Over-current Protection
Rated residual operating current
I∆n = 30 mA: additional protection in the case of direct contact.
Tripping class
AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
CATALOG
NB3LE Residual Current Operated Circuit Breaker with Over-current Protection PDF
NB1L Residual Current Operated Circuit Breaker with Over-current Protection(Magnetic)
1.1 Function
Personnel and fire protection: Cable and line protection against overload and short-circuits.
1.2 Selection
Rated residual operating current
I∆n ≤30 mA: additional protection in the case of direct contact.
I∆n ≤300 mA: preventative fire protection in the case of ground fault currents.
Tripping class
AC class
Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase.
A class
Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
NB1L Residual Current Operated Circuit Breaker with Over-current Protection PDF
NXB-125 Moulded Case Circuit Breaker
Rated current: 63A, 80A, 100A, 125A;
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icu): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125 Moulded Case Circuit Breaker PDF
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
CATALOG
NB1-63DC DC Miniature Circuit Breaker PDF
DZ158 Moulded Case Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
DZ158 Moulded Case Circuit Breaker(DC type)