NJB1-X1 Relay
NJB1-X1 relay (phase sequence, phase failure protection) is used as an phase sequence and phase failure protection device in control circuits with an AC voltage of 200V~500V and a frequency of 50Hz to make and break the circuit. It cannot monitor the phase failure of motor load.
SKU: ELC7078
Categories: Electrical Products, Low Voltage Electric, Protection Relay, Relays
Tags: Low voltage electric, Protective Relay, Relay
Related products
NB1-63 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-14In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
NXB-40 Miniature Circuit Breaker
Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A;
Rated voltage: 240V;
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P+N;
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles;
Rated short-circuit breaking capacity(Icu): 4500A;
Short-circuit breaking capacity(Ics): 4500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-40 Miniature Circuit Breaker PDF
NB1-63G Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currentsprotection of circuits against overload currents,switch,isolation,
NB1-63G circuit-breakers are used in domestic installation,as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point consideredshort-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,
Network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrus current.
CATALOG
NB1-63G Miniature Circuit Breaker PDF
HDLRT0 Fuse for Distribution
HDLRT0 Fuse for Distribution
1.Electric ratings: AC50Hz, AC380V/DC400V, up to 1000A;
2.Application: for protection of power distribution apparatus against over-load and short circuit;
3.Standard: IEC 60269.