NXB-63 Miniature Circuit Breaker
Overload protection, short circuit protection and isolation. It is widely used in building power distribution, industrial power distribution, as well as control and protection for a variety of equipment with operating current not exceeding 125A.
SKU: ELC44334
Categories: Electrical Products, Low Voltage Electric, MCB, Modular DIN Rail Products
Tags: Circuit Breaker, MCB
Related products
NBH8LE Residual Current Operated Circuit Breaker with over-current protection (Electronic)
1.1 Function
Personnel and fire protection
Cable and line protection against overload and short-circuits.
1.2 Selection
I∆n = 10mA, 30mA: additional protection in the case of direct contact.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits;
protection for resistive and inductive loads with low inrush current.
AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase.
CATALOG
NBH8LE Residual Current Operated Circuit Breaker with over-current protection PDF
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection
1.1 Selection
Rated residual operating current
I∆n = 30 mA: additional protection in the case of direct contact.
Tripping class
AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big
length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.2 Approvals and certificates
CATALOG
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection PDF
NB1L Residual Current Operated Circuit Breaker with Over-current Protection(Magnetic)
1.1 Function
Personnel and fire protection: Cable and line protection against overload and short-circuits.
1.2 Selection
Rated residual operating current
I∆n ≤30 mA: additional protection in the case of direct contact.
I∆n ≤300 mA: preventative fire protection in the case of ground fault currents.
Tripping class
AC class
Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase.
A class
Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
NB1L Residual Current Operated Circuit Breaker with Over-current Protection PDF
NXB-40 Miniature Circuit Breaker
Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A;
Rated voltage: 240V;
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P+N;
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles;
Rated short-circuit breaking capacity(Icu): 4500A;
Short-circuit breaking capacity(Ics): 4500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-40 Miniature Circuit Breaker PDF
NB7 Miniature Circuit Breaker
The NB7 series miniature circuit breaker is applicable to the circuit with an alternating current of 50Hz/60Hz, rated voltage of 240/415V, and rated current up to 63A for overload protection and short circuit protection, and also for not-frequent operational transformation in the circuit under normal condition.
This product can be applied to various places such as industrial, commercial, and tall buildings, and residential houses.
The product meets the standards of IEC60898-1.
NB7 Miniature Circuit Breaker PDF
NXB-125G Miniature Circuit Breaker
Rated current: 63, 80, 100(1P, 2P, 3P, 4P), 125(1P, 2P);
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: B, C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icn): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG